background image

Product Overview 

PRODUCT OVERVIEW 

LCD Display

HR-LCD encoders have a nine-digit Liquid Crystal Display (LCD) to show consumption, flow and alarm information .
There is no need to activate the display . The display automatically toggles between consumption (segmented leak detector in 

this mode), rate of flow and meter model .

OTEE:

N

Devices are shipped in storage mode so that a meter status alarm is not triggered . In storage mode, the meter model 

screen is displayed . 

Multiplier Value

Depending on the meter model, size and unit of measure, a multiplier value may also be shown . Multiply the displayed value 

by the multiplier value to calculate the reading to the nearest gallon, cubic foot, or cubic meter .  

ExampleE: 123456 (displayed value) x 10 (multiplier value) = 1234560

Extended Visual

Reading Resolution

Typical Billing

Segments

Status

Indicators

IR Programming

Port

00/00

4-Digit

Date Code

E LCD

HR

Multiplier Value

(x10, x100, x1000, x10,000)

In 6-digit mode, the 

last digit is a dashed

line that becomes a

flow finder

Figure 1:  HR-E LCD encoder face

Visual Display

Units of Measure

The units of measure are factory-programmed and user-programmable . Options include U .S . gallons, Imperial gallons, cubic 

feet, cubic meters and liters .

9-Digit Totalization

The consumption display includes all nine digits and a decimal point (based on meter model, size and unit of measure) . The 

displayed value is the sum of the forward flow minus any reverse flow . This screen displays for 45 seconds .

Model 25 Disc Series Meter Calibrated in Gallons

4

GAL

Page 4 

April 2019

LCD-UM-01482-EN-07

Содержание HR-E LCD

Страница 1: ...12 27 or higher does not include extended status indicator capabilities ReadCenter Analytics and ReadCenter Analytics Mobile Version 2 12 7 6 or later Mobile Reading Systems ORS Version 2 2 1 or late...

Страница 2: ...isplay 4 Units of Measure 4 9 Digit Totalization 4 6 Digit Totalization 5 Rate of Flow 5 Meter Model Information 5 Installing the Encoder 6 Bayonet Mount 6 Wire Connections 6 HR E LCD 6 HR E LCD 4 20...

Страница 3: ...evices come standard as factory programmed with the option for programming in the field Programming is performed through the device IR port via a computer The programming kit PN 67660 001 can be order...

Страница 4: ...ot or cubic meter Example 123456 displayed value x 10 multiplier value 1234560 Extended Visual Reading Resolution Typical Billing Segments Status Indicators IR Programming Port 00 00 4 Digit Date Code...

Страница 5: ...display is shown without leading zeros A reverse flow is indicated by a minus sign before the flow rate The displayed rate will be based on the average flow rate for the prior minute since the last ti...

Страница 6: ...fer to the document ORION Water Endpoints Installation Manual available at www badgermeter com HR E LCD The HR E LCD encoder has a single cable available with three different wiring options Refer to F...

Страница 7: ...1 High Side T1000 4 0 1 0 01 0 001 Low side M35 4 0 01 0 001 0 0001 High Side T2000 6 1 0 1 0 01 Low Side M35 6 0 01 0 001 0 0001 High Side T3500 8 1 0 1 0 01 Low side M120 8 0 1 0 01 0 001 Endpoint R...

Страница 8: ...s Firmware version 1 8 or higher required Meter functioning correctly Encoder operating correctly Continuous display on encoder as long as no other status indicators are triggered Indicator status not...

Страница 9: ...1 40 M55 1 0 01 0 001 0 0001 55 M70 1 0 01 0 001 0 0001 70 M120 1 1 2 0 1 0 01 0 001 120 M170 2 0 1 0 01 0 001 170 Recordall Turbo Series Size in Encoder Output Analog Output 9 dial gal 9 dial ft3 9 d...

Страница 10: ...ing resolution sent to the reading software is dependent on the endpoint that the encoder is connected to Readings reported from the endpoints are the left most significant digits of the encoder readi...

Страница 11: ...gratable Endpoints Firmware version 1 8 or higher required Meter functioning correctly Encoder operating correctly Continuous display on encoder as long as no other status indicators are triggered Ind...

Страница 12: ...800 876 3837 414 355 0400 M xico Badger Meter de las Americas S A de C V Pedro Luis Ogaz n N 32 Esq Angelina N 24 Colonia Guadalupe Inn CP 01050 M xico DF M xico 52 55 5662 0882 Europe Eastern Europe...

Отзывы: