B – corresponds to error codes 8 + 2 + 1
C – corresponds to error codes 8 + 4
D – corresponds to error codes 8 + 4 + 1
E – corresponds to error codes 8 + 4 + 2
F – corresponds to error codes 8 + 4 + 2 + 1
If at least one digit value of an error code is ≥8, the summing-up of energy, water quantity, and trouble-free operation time
is stopped
In case of the flow sensor error 4, the time “when the flow q> 1 2∙qs” is recorded additionally
Test Mode Control
Test Mode Specifications
Test Mode
(TEST) is intended for quick testing
Test Mode
can by activated by the control button, through optical interface or by the jumper
In the
Test Mode
, the meter:
• indicates the increased resolution energy and flow values;
• forms energy or volume pulses through the optical interface;
• forms energy pulses at the 1st pulse output and volume pulses at the 2nd pulse output (when the meter is fitted with a
pulse input/output cable);
• can simulate water volume for determining the energy measurement error tolerance (only when
Test Mode
is activated by
the jumper)
The resolution of energy and flow rate indicators in the
Test Mode
(TEST) is presented in
Selected energy measurement units
kWh, MWh
GJ
Gcal
Resolution of the energy indicator
000000 01 Wh
0000000 1 kJ
0000000 1 kcal
Resolution of volume indicator
00 000001 m
3
Table 2: Resolution of energy and flow rate indicators in the Test Mode
The values of energy and volume test pulses (through the optical interface and at pulse outputs), depending on the
permanent flow rate value, are presented in
Permanent flow value,
q
p
, m³/h
Volume pulse
value, l/pulse
Energy pulse value, when energy measurement units are selected asE:
kWh, MWh
GJ
Gcal
0 6
0 002
0 1 Wh/pulse
0 5 kJ/pulse
0 1 kcal/pulse
1 0
0 002
0 2 Wh/pulse
1 kJ/pulse
0 2 kcal/pulse
1 5
0 004
0 2 Wh/pulse
1 kJ/pulse
0 2 kcal/pulse
2 5
0 005
0 5 Wh/pulse
2 kJ/pulse
0 5 kcal/pulse
3 5
0 02
1 Wh/pulse
5 kJ/pulse
1 kcal/pulse
6 0
0 02
1 Wh/pulse
5 kJ/pulse
1 kcal/pulse
10 0
0 05
2 Wh/pulse
10 kJ/pulse
2 kcal/pulse
15 0
0 05
5 Wh/pulse
20 kJ/pulse
5 kcal/pulse
25
0 05
5 Wh/pulse
20 kJ/pulse
5 kcal/pulse
40
0 2
10 Wh/pulse
50 kJ/pulse
10 kcal/pulse
60
0 2
10 Wh/pulse
50 kJ/pulse
10 kcal/pulse
Table 3: The values of energy and volume test pulses (through the optical interface and at pulse outputs), depending on the permanent flow rate value
Operating Procedure
Page 28
November 2020
HYB-UM-03193-EN-02