PAGE 18
SERVICE SECTION
SECTION 1:
HYDROSTATIC SYSTEM
The hydro reservoir tank on the Outlaw model is located
on each side of rear cover. Notice the “full cold” line at the
bottom of the tank. Use only 20W-50 motor oil in this
tank. Conventional or synthetic oil may be used.
THE FOLLOWING MAINTENACE IS TO BE
PERFORMED ON A LEVEL SURFACE.
Outlaw transaxles hold 4 quarts of 20W-50 motor oil
each. Bad Boy Hydrostatic Oil is recommended.
Transaxle service is recommended after the first 75 hours
of use; then at intervals of 250 usage hours. Use only
Hydro-Gear® brand oil filters. Use of other brands could
void the warranty.
CHANGING YOUR HYDRAULIC OIL AND FILTER
OUTLAW 4400
1.
Place an oil drain pan (12” or more in diameter
and 8 qt. capacity is optimal) beneath the oil
filter.
Remove the oil filter cover from the
transaxle to
drain the oil. Remove the O-ring from
the cover
and discard the O-ring.
2.
After the oil has drained from the transaxle,
remove the oil filter from the transaxle housing.
3.
Install a new filter and a new O-ring onto the filter
cover and install the filter cover. Torque the filter
cover to 200-300 in-lbs.
4.
Fill the transaxle with new 20W-50 motor oil
through the hydraulic reservoir until it reaches the
cold fill line on the tank.
5.
Drain the old oil filter of all free-flowing oil prior to
disposal. Place used oil in appropriate containers
and deliver to an approved recycling collection
facility.
6.
Proceed to the purge procedure on the page 20.
7.
Recheck oil level and fill as necessary.