The Informant Refrigerant Leak Detector
8
Instruction
0019-9210
Technical Characteristics
Switches:
Power ....................................... Toggles detector ON/OFF
Mute......................................... Toggles audible indicator ON/OFF, and
Toggles Low-Sensitivity Mode ON/OFF
when switch is held down >¾ second
Sampling System Flowrate ...... 40 to 50 cc/min with sensor installed
Response Time ........................... 0.2 second
Sensitivity:
Normal
..................................... 0.5 oz/year (14 g/yr) of R134a (hardest to
detect refrigerant) as detected by mov-
ing probe tip at 2" (50 mm) per second,
0.1" (3 mm) above leak source. A leak rate
of less than 0.25 oz/year (7 g/yr) can be de-
tected when probe tip is held steady over
leak source for at least 5 seconds.
Low .......................................... 1/10 of normal
Sensitivity Adjustment .............. Automatic – in either sensitivity mode
Weight ........................................ 0.86 lb (0.39 kg) w/ batteries
Size (excluding probe) ............... 1.75W x 9.62L x 2.25H inches
(44.5 x 244.3 x 57.2 mm)
Probe Length .............................. 20" (508 mm)
Operating Environment:
Position
.................................... Any
Temperature ........................... 32 to 122 °F (0 to 50 °C)
Humidity ................................. 15 to 90% RH, non-condensing
Approvals .................................... CE Mark & UL listed in accordance to
SAE J1627