4 - 37
Adjustment
In
spection and
Adjustment
Camera calibration
6. Press the
button, and image processing result is displayed
about 20 seconds later. (Fig. 4)
*Key point
• “O” is success, “X” is no good.
• When the “X” is displayed on the screen, press the
button, and then start again from the procedure 5.
7. Remove the pattern sheet from the machine.
8. Attach the #11 needle.
9. Set the white plain paper (A4 or letter size) to the machine.
(Fig. 5)
*Note
• Do not use the glassy (shiny) paper.
• No dirt and fold on the paper.
10. Turn the pulley by hand, and insert the needle into the paper until
the center of the needle hole. (Fig. 6)
*Note
• After inserting the needle, make sure there is no space
between the paper and the needle plate.
• Do not insert the needle lower than the needle hole (Needle
hole must be seen).
<To next page>
Fig. 4 (Success)
Needle hole
Needle
Paper
Fig. 5
Fig. 6