4 Design and Construction
24
DHV0053 b2 EN
©
b2electronic
gmbh
Output Mode
Characteristics
Sheath Test
•
Suitable for Sheath Test
•
Duration is user defined
•
Unmax 10 kV
Sheath Fault
Location Mode
•
Suitable for Sheath Fault Location
•
Duration is user defined
•
Pulse user defined
(1:3/4 s, 1:5/4 s, 1:5/6 s, 1:9/6 s)
Arc Management Modes
If a fault is detected during a HV test, the arc management mode determines
how the failure is managed. The “Burn on Arc” mode will condition the fault
whereas the “Trip out on Arc” mode will immediately switch HV off.
Fault detected
Burn on Arc
Trip Out on Arc
Dwell time Starts
Dwell Time Ends
DUT energizes
Fault detected
Fault conditioned
DUT discharges
HV automatically
OFF
Tripping time
recorded
HV still
ON