Trigger
62
Edge Trigger
The edge trigger type identifies a trigger by looking for a specified edge (rising, falling, or alternating) and
voltage level on a waveform. The trigger type, source, and level are displayed in the lower-center of the
display.
Figure 5.9
Edge Trigger
Alternating edge mode is useful when you want to trigger on both edges of a
clock (for example, DDR signals).
The easiest way to set up an Edge trigger on a waveform is to use Autoscale. Simply press the
button and the oscilloscope will attempt to trigger on the waveform using a simple Edge trigger type and
rising slope.
Holdoff, coupling and noise reject can be set in edge trigger, see the sections
,
, and
.
To set the slope of the edge trigger:
1. Press the
button to enter the trigger menu.
2. Press the
button to select
Slope
.
• A dropdown menu containing the available options will appear.
Figure 5.10
Slope
3. Use the
to navigate the available options.
• Repeately pressing
will navigate between the available choices.