HP2
Shallow Housing - Standard MR16 & PAR36/AR111
Remote Transformer Installation
RELEASE DATE
10/13/2021
REFERENCE NUMBER
INS-2856-00
40429 Brickyard Drive • Madera, CA 93636 • USA
559.438.5800 • FAX 559.438.5900
www.bklighting.com • [email protected]
B-K LIGHTING
IMPORTANT SAFETY INFORMATION LISTED ON REVERSE
READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS
7. Remove any dirt or debris in o-ring groove near
top of housing. Place o-ring inside of groove.
Failure to clean groove of debris will cause
fixture to fail and void product warranty.
8. Install faceplate using a 1/8” allen wrench and
hand-tighten the faceplate screws in a star
pattern to 30 in-lbs. min.
Do not use a power tool to install screws. Do not
exceed 40 in-lbs.
FOR USE WITH PAR36/AR111
6b.
For Optional Accessory Holder:
Insert
accessory holder tabs onto arms on OptiLock.