SPECIFICATION
GENERAL
The Super Halcyon 3 sensor unit and the analogue compass repeater are fully sealed for use in
marine conditions.
PERFORMANCE
Sensor Accuracy (when properly adjusted):
+ 1
°
max. error at 0
°
heel
+ 2
°
max. error at 20
°
heel
+ 3
°
max. error at 30
°
heel
Repeater Accuracy
: +1.5
°
max. error
Temperature Range
: -10
°
C to +60
°
C
Relative Humidity
:
0 – 100%
Earth’s field strength range (Horizontal component):
5 to 45 microTesla (equator to 80
°
latitude)
Maximum number of indicators
: 3
Maximum heading rate
: 33
°
/second
Response Time
: minimum 0.25 seconds
Calibration turn rate:
Maximum 3
°
/second
Minimum 0.2
°