Automatic Calibration Inhibit 

 
The manoeuvres involved in carrying out the automatic calibration are selected in order to make 
accidental re-calibration very unlikely. Even if this should occur, this represents no real inconvenience 
to the navigator, but where ship operating regulations demand it, the calibration may be inhibited by 
disconnecting the brown wire from the compass at the junction box , cutting it back and insulating it. 
This facility is only available with installations using a junction box. 
 
 

Manual Initiation of Calibration 

 
Should a calibration run be required with the junction box wiring modified as described in the 
Automatic Calibration Paragraph, prepare to make the run as for an Automatic Calibration, and then 
connect a wire between the brown and black terminals as indicated by the dotted line in the wiring 
diagram for ten seconds. The procedure described in the Automatic Calibration procedure can then be 
performed. 
 
 

TECHNICAL DATA 

 
The main output from the Super Halcyon 3 can be connected directly with the B&G Hercules system. 
It can also drive the analogue repeater compass directly. 
 
Three other outputs are available from the standard compass (386-00-009) to interface with a wide 
range of autopilots, radars, position fixers, computers etc. 
 
(a) A three-wire analogue output, 2.5 ref/sine/cosine. 
 
(b) A digital output which can be configured to N+1 format, or to 1/6

°

 step Gray Code format (gyro). 

 
(c) An NMEA interface which can also be used with the RS232 port of a computer. 
 
For the latest information on interfacing, please contact your nearest B&G service agent. The Output 
configuration of your compass is indicated by a code on a label attached to the sensor unit. 
 
 

Output 

Standard 

Setting 

Code 

3-Wire Sine/Cosine 
With Internal 2.5V Ref. 
With External 2.5V Ref. 

 

’

 

 

Digital Output: 
     Stepper 
     N+1 
     Open Collector 
     5V 

 

’

 

 

’

 

 

 


NMEA Sentence Output: 
     $HCDM 
     $HCHSC 
     $HCVHW 

 

’

 

 

Damping: 
     0.3 – 99 Seconds 

0.3  

 

Содержание Super Halcyon 3

Страница 1: ...UAL Premier Way Abbey Park Romsey Hampshire S051 9DH England Tel 44 01590 689699 Fax 44 01590 610072 Web www bandgservice co uk Brookes Gatehouse Ltd 1987 The copyright of this Manual is the property...

Страница 2: ...ASS INDICATOR 3 OPERATION 4 FAULT LOCATION 5 ALL OUTPUTS DEFECTIVE 5 DIGITAL OUTPUTS 5 INSTALLATION 6 MASTER COMPASS UNIT 6 CONNECTIONS SEE FIG 1 7 CALIBRATION 8 AUTOMATIC CALIBRATION 8 COMPASS CALIBR...

Страница 3: ...when connected to the Hercules system COMPASS UNIT One important feature of the Super Halcyon 3 is its ability to learn the magnetic effect of the vessel on the compass and automatically apply deviat...

Страница 4: ...dification See section 5 on automatic calibration All outputs are protected against accidental short circuit In the event of a short circuit the compass will switch off To return to normal operation f...

Страница 5: ...nd rectify the short circuit switch off the supply for a few seconds and then switch on the power again If heading rotates in wrong direction reverse any two phases The compass will step from 0 to cur...

Страница 6: ...e automatic compass calibration but that of moveable gear cannot Avoid proximity to any locker where items containing iron or steel e g tools cameras audio and video tapes books with steel ring binder...

Страница 7: ...r unit about a vertical axis The variation in displayed heading will be clearly shown on either the repeater or on the Hercules digital display note that for easy reading the latter is heavily damped...

Страница 8: ...oat completes a 540 one and a half circles turn provided a The 540 turn is completed without changing the direction of the turn b The rate of change of heading does not exceed 3 second during the 540...

Страница 9: ...is discarded 2 When the compass has completed the calibration the displayed heading will rotate in the opposite direction for 360 and settle on the correct bearing to indicate that the calibration is...

Страница 10: ...conds The procedure described in the Automatic Calibration procedure can then be performed TECHNICAL DATA The main output from the Super Halcyon 3 can be connected directly with the B G Hercules syste...

Страница 11: ...rror at 0 heel 2 max error at 20 heel 3 max error at 30 heel Repeater Accuracy 1 5 max error Temperature Range 10 C to 60 C Relative Humidity 0 100 Earth s field strength range Horizontal component 5...

Страница 12: ...ship s supply negative Heading 0 90 180 270 Red Wire Cos 1 5V 3 5V 5 5V 3 5V Green Wire Cos 5 5V 3 5V 1 5V 3 5V Cosine Output Violet Wire Sin 3 5V 1 5V 3 5V 5 5V Blue Wire Sin 3 5V 5 5V 3 5V 1 5V Sin...

Страница 13: ...External reference is available Please consult your dealer for details Digital Output This is a stepper output using the 3 phase Gray code D1 D2 open collector up to 50V or 5V 10mA D3 External resisto...

Страница 14: ...e with a computer RS232 link POWER SUPPLY Voltage 10V 30V dc lighting for repeater 12V Current Drain typical 55mA No indicator 135mA 2 indicators 95mA 1 indicator 175mA 3 indicators Output Protection...

Страница 15: ...ed Cosine ve Violet Sine ve Blue Sine ve B G 4 Wire Output Yellow Red NMEA Input ve White Red NMEA Input ve Green Brown NMEA Output ve Pink Sine Yellow Cosine Grey 2 5V Reference B G 3 Wire Output Red...

Отзывы: