47
•
Azkoyen does not recommend the use of socket extenders. If these need to be used, the
cables must have a minimum cross-section of 1.5 mm
2
and the manufacturer
’
s
recommendations must be observed
•
Guide the power supply cable
so it
is not in contact with sharp surfaces
or ensure it cannot
become snagged
by nearby objects. Keep the power supply cable far from sources of heat.
3.1.7
Power consumption
•
Maximum consumption of Vitro M5 with the Fresh Milk module: 2,400 W
•
Maximum consumption of the FG16i DGT refrigerator: 100 W
•
2 sockets with a grounding connection are required to connect both modules (VM5 +
Refrigerator), according to the electrical safety regulations.
CAUTION
Risk of causing material damage by flooding due to problems in the water
installation.
3.1.8
Water connection
The machine may suffer damage and its useful life may be reduced if the following work conditions
are not respected.
•
The network water must be free from contaminating substances and the
chlorine content
must not exceed 50 mg/litre
.
•
Do not connect the machine to a reverse osmosis unit or other types of hard water
supplies.
•
The network water
hardness
must be between
6
–
9 Dkh
(German hardness scale).
•
The water connections must comply with the local regulations of the country where the
machine will be installed.
•
According to the Low-Voltage Regulations, the distance between the water socket and
any electrical socket base must be of at least 1 metre.