10095 UK 09 - 2004
Technical Information:
HOPPER U
3
Small hopper
Medium hopper
Large hopper
L=115 mm and 250 coins
L=115 mm and 400 coins
L=115mm and 600 coins
Ô
Microprocessor controlled PCB control board.
Ô
Anti jam and anti span systems.
Jams.
These hoppers have a current draw detection system to manage the possible
coin jams that may occur. When the detection system activates, the spin of the hopper
motor is reversed for 1.5 seconds to free the jammed coins.
Spans
. The time span between the extractions of two coins is called a span. When a
span of more than five second is detected, the hopper reverses the movement of the
motor for 1.5 seconds to move the coins in the coin bay so that after the movement
the coins are in a better position to be extracted.
Ô
Auto detection of errors and faults. Depending on the communication protocol used,
the number of errors that are detectable will be different.
Ô
A useful life of 2 million coin extractions.
Ô
Different systems to control the filling if the hopper: optic sensors, mechanical scales
or overflow.
Ô
Empty detection using optic sensors.
Ô
Different communication protocols with the machine: serial or parallel.
When using parallel protocol the machine manages all the signals separately: one
wiring loom for each hopper.
When using cctalk communication protocol, the communication is carried out through a
bidirectional data line (DATA). This solution radically simplifies the wiring and therefore
the cost of the machine.
Содержание Hopper U 3030 Series
Страница 2: ...10095 UK 09 2004 Technical Information HOPPER U 1 U HOPPER ...
Страница 14: ...10095 UK 09 2004 Technical Information HOPPER U 13 5 PINOUT Serial communication ...
Страница 15: ...10095 UK 09 2004 Technical Information HOPPER U 14 cctalk with 3 wires for and 3 for ...
Страница 16: ...10095 UK 09 2004 Technical Information HOPPER U 15 Parallel ...
Страница 17: ...10095 UK 09 2004 Technical Information HOPPER U 16 Parallel with full and empty sensors ...
Страница 18: ...10095 UK 09 2004 Technical Information HOPPER U 17 Parallel without full and empty sensors ...
Страница 19: ...10095 UK 09 2004 Technical Information HOPPER U 18 Parallel pin 10 is used for the full sensor ...
Страница 20: ...10095 UK 09 2004 Technical Information HOPPER U 19 Parallel plug play ...
Страница 21: ...10095 UK 09 2004 Technical Information HOPPER U 20 Parallel plug play and no empty sensor ...
Страница 22: ...10095 UK 09 2004 Technical Information HOPPER U 21 Standard CCTALK ...
Страница 23: ...10095 UK 09 2004 Technical Information HOPPER U 22 Standard cctalk with 2 wires for and 2 for ...
Страница 24: ...10095 UK 09 2004 Technical Information HOPPER U 23 Plug play For cigarette vending machines ...
Страница 25: ...10095 UK 09 2004 Technical Information HOPPER U 24 Brands of the AZKOYEN AZKOYEN MEDIOS DE PAGO S A ...