background image

 

 

10095 UK      09 - 2004 

 

Technical Information:

 HOPPER U        

 

      

                              6

 

capacities and sizes. 

 

Coin bays 

Hopper Coin 

capacity 

 

Ø 24 mm 

 Thickness 2.8 mm 

€ cents 

10 

€ cents 

20 

€ cents 

50 

€ cents 

€1 

 

€2 

 

Small 

250 

450 450 350 250 275 225 

Medium 

400 

775 775 600 375 425 325 

Large 600 

1,100 

1,100 

975 

700 

750 

650 

2.   Moving flap

 

This element is used to move the coins and dose the flow of coins that reach the 

extractor disk

Another function is to avoid the pressure of an excessive number of coins on the

 extractor disk

.

 

3. 

Mechanical supplement of greater capacity for the coin bay 

This element is a coin bay accessory that increases its capacity. There are different models and 

sizes for each of the different types of hoppers.  

4. 

Hopper full detection system 

There are three ways of controlling when the hopper is at full state: 

Overflow

: a mechanic system that is based on the overflow of coins using gravity. The 

coin capacities of these hoppers are the following: 

 

Capacities of the hoppers with overflow 

Hopper Coin 

capacity 

 

€ cents 

10 

€ cents 

20 

€ cents 

50 

€ cents 

€1 

 

€2 

 

Small 

N/A 

     

Medium 430 430 350 225 300 250 

Large 

N/A 

 

 

 

 

 

 

Infrared photocells

: an electronic system that uses two infrared photocells. 

Scales:

 based on controlling the weight of the coins in the hopper. When the weight of 

the hopper full of coins compresses the spring, which is regulated with a screw, a micro 

switch is activated. The 

Scales

 are an accessory of the 

hopper

 that are installed on the 

underside and incorporate a base for its correct installation. 

 

Содержание Hopper U 3030 Series

Страница 1: ...rocoin co uk TEL 44 208 275 3000 sales eurocoin co uk Product Description Azkoyen Hopper U Original Manufacturer Eurocoin Part Number Current Revision Date of Release Azkoyen 3030xxxx Rev 1 Sept 2 0 0 4 Document Content Summary Technical Manual ...

Страница 2: ...10095 UK 09 2004 Technical Information HOPPER U 1 U HOPPER ...

Страница 3: ...as hopper or hoppers These hoppers have a multicoin extraction system The multicoin concept defines the fact that these hoppers can return or pay out a coin whose measurements are from 12 to 32 mm in ø and 1 2 to 3 5 mm in thickness 1 1 TECHNICAL CHARACTERISTICS AND A DESCRIPTION OF COMPONENTS The most relevant technical and performance characteristics are Ô Multicoin extraction system Ô Power sup...

Страница 4: ...or 1 5 seconds to move the coins in the coin bay so that after the movement the coins are in a better position to be extracted Ô Auto detection of errors and faults Depending on the communication protocol used the number of errors that are detectable will be different Ô A useful life of 2 million coin extractions Ô Different systems to control the filling if the hopper optic sensors mechanical sca...

Страница 5: ...Ô The configuration of the node addresses is carried out using the dip switches situated on the PCB which is situated on the underside of the hopper as shown in the illustration When using Cctalk protocol address 1 is the machine 2 is the validator 3 is the first hopper 4 is the second hopper 5 is the third hopper 6 is the fourth hopper etc ...

Страница 6: ... 4 ON OFF 3 5 ON ON 4 6 When using cctalk protocol the addresses can also be configured by software using Cctalk protocol MDCES commands reaching a maximum of 253 addressable nodes 1 2 DESCRIPTION OF COMPONENTS 1 Coin bay This element of the hopper holds the coins There are various models with different coin ...

Страница 7: ...nd sizes for each of the different types of hoppers 4 Hopper full detection system There are three ways of controlling when the hopper is at full state Overflow a mechanic system that is based on the overflow of coins using gravity The coin capacities of these hoppers are the following Capacities of the hoppers with overflow Hopper Coin capacity 5 cents 10 cents 20 cents 50 cents 1 2 Small N A Med...

Страница 8: ...er The hoppers can have two types of blade Long blade for disks of 7 and 8 ridges Short blade for disks of 12 ridges 7 Trigger In the coin extraction process this device compresses the trigger spring and at a certain point it shoots the coin out of the hopper These hoppers can have two types of trigger Trigger without a roller for coins with a diameter of over 30 mm Trigger with a roller for coins...

Страница 9: ... coin can be extracted from the hopper Its electrical characteristics are as follows Current draw 12 Vdc 24 Vdc Rest 75 mA 75 mA Start up 3 A 2 5 A Spinning 450 mA 310 mA 11 Base This element is a hopper accessory that is used to join the hopper to the machine in which it is installed It has all the necessary holes to fix it to the machine and clips to hold the hopper for fast assembly disassembly...

Страница 10: ...10095 UK 09 2004 Technical Information HOPPER U 9 It also guides the coins toward a second hopper when two hoppers are mounted together in the configuration called cascade ...

Страница 11: ... 3ºon all axes z Temperatures Ô Storage from 25 to 70ºC Ô Working from 5 to 55ºC z Humidity maximum 95 relative humidity without condensation z Physical characteristics of the coins that are admissible z Norms that are met Ô EN50081 1 general emission norm Ô EN50022 conductive emission Ô EN50022 radiation emission Ô EN50082 1 general immunity norm Ô IEC801 2 electrostatic discharges ESD measuremen...

Страница 12: ... 500 000 coin extractions It is recommended to clean the coin exit area where the optic sensors are more frequently This can be done with cotton wool bud dipped in alcohol WARNING Ô Never use products that contain benzene hydrocarbons These products severely degenerate the plastic parts producing irreparable damage Ô Never submerge the Discriminator series hopper in any liquid ...

Страница 13: ... 2004 Technical Information HOPPER U 12 4 DIMENSIONS AND VOLUMES Hopper without overflow Hopper L mm Small 115 Medium 154 Large 228 Hopper with overflow Hopper L mm Medium 191 Large 228 Hoppers mounted in cascade ...

Страница 14: ...10095 UK 09 2004 Technical Information HOPPER U 13 5 PINOUT Serial communication ...

Страница 15: ...10095 UK 09 2004 Technical Information HOPPER U 14 cctalk with 3 wires for and 3 for ...

Страница 16: ...10095 UK 09 2004 Technical Information HOPPER U 15 Parallel ...

Страница 17: ...10095 UK 09 2004 Technical Information HOPPER U 16 Parallel with full and empty sensors ...

Страница 18: ...10095 UK 09 2004 Technical Information HOPPER U 17 Parallel without full and empty sensors ...

Страница 19: ...10095 UK 09 2004 Technical Information HOPPER U 18 Parallel pin 10 is used for the full sensor ...

Страница 20: ...10095 UK 09 2004 Technical Information HOPPER U 19 Parallel plug play ...

Страница 21: ...10095 UK 09 2004 Technical Information HOPPER U 20 Parallel plug play and no empty sensor ...

Страница 22: ...10095 UK 09 2004 Technical Information HOPPER U 21 Standard CCTALK ...

Страница 23: ...10095 UK 09 2004 Technical Information HOPPER U 22 Standard cctalk with 2 wires for and 2 for ...

Страница 24: ...10095 UK 09 2004 Technical Information HOPPER U 23 Plug play For cigarette vending machines ...

Страница 25: ...10095 UK 09 2004 Technical Information HOPPER U 24 Brands of the AZKOYEN AZKOYEN MEDIOS DE PAGO S A ...

Отзывы: