Te ch n ica l I n for m a t ion :
HOPPER U – I I cct alk
1 9
Pin
Fu n ct ion
1,2,3 Vdc
4,5 GND
6 Full
7 Cont rol
8 Error
9 Coin
10 Em pt y
Figur e 1 5 . Pin ou t H oppe r U- I I con ve n t ion a l w it h full a nd e m pt y de t e ct ion .
Con n e ct or for t h e con t r ol of t h e w or k in g logic.
Using connect or 6 in figure 9 you can select t he working m ode of t he Hopper U- I I for t he
cont rol of signal levels.
Posit ion of t h e pin s
W or k ing m ode s
Cont rol wit h negat ive logic
digit al signal
Cont rol wit h posit ive logic
digit al signal
Cont rol by pulses
Figur e 1 6 . Type s of con t r ol of t h e w or k ing m ode
Consult t he m anual “ Prot ocol convent ional Hopper U- I I _v0.doc” t o see det ails of t he
convent ional prot ocol.
Con n e ct or for con t r ol of t h e com m u n ica t ion .
Wit h configurat ion of connect or 7 in figure 9, you can configure t he working m ode of t he
Hopper U- I I , as shown in figure 17:
Posit ion of t h e pin s
W or k ing m ode s
St andard
Plus
St andard
Figur e 1 7 . Configu r a t ion H oppe r U- I I st a nda r d or plu s.
10239 EN 03 - 2007