Te ch n ica l I n for m a t ion :
HOPPER U – I I cct alk
6
Sm a ll hoppe r
M e diu m H oppe r
I n t e r m e dia t e hoppe r
La r ge h oppe r
L= 115m m and
2 5 0
coins
L= 154 m m and
4 0 0
coins
L= 189 m m and
5 2 5
coins
L= 228m m and
6 0 0
coins
Coin s of Ø 2 4 m m
a n d t h ick n e ss 2 .8
m m
Coin s of Ø 2 4 m m
a n d t h ick n e ss 2 .8 m m
Coin s of Ø 2 4 m m
a n d t h ick n e ss 2 .8 m m
Coin s of Ø 2 4 m m
a n d t h ick n e ss 2 .8 m m
Figu r e 1 . H oppe r U- I I
Consult sect ion “
t o see t he exact capacit ies depending on t he size of coin, and also
t he supplem ent s.
2 .2 .
RAN GE OF COI N S.
The m ult icoin ext ract ion syst em of t he hopper U- I I , guarant ies t he payout of coins whose
dim ensions are bet ween 1.2 and 3.5 m m t hick, and 12 t o 32 m m in ø.
Consult sect ion “
for m ore det ails.
2 .3 .
D ETECTI ON OF FULL AN D EM PTY
The Hopper U- I I has det ect ion m echanism s t hat det ect t he full and em pt y levels of t he coins in
t he coin bay.
The det ect ion of em pt y is done by using an elect ronic infrared phot ocell syst em . ( See det ails in
sect ion
“
The det ect ion of full is carried out in t w o different ways:
-
Using t w o infrared phot ocells t hat w ork in t he sam e w ay as t he em pt y det ect ion phot ocells.
( See det ails in sect ion
“
) .
-
Using elect rom echanical scales. ( See det ails in sect ion
“