Azbil KFDB Скачать руководство пользователя страница 45

(1)  For use under such conditions or in such environments as not stated in technical documents, including catalogs, specification, 

and instruction manuals 

(2)  For use of specific purposes, such as: 

*   Nuclear energy/radiation related facilities  

[When used outside a radiation controlled area and where nuclear power quality is not required]  
[When the limit switch for nuclear power is used]

*  Machinery or equipment for space/sea bottom 
*  Transportation equipment 
 

[Railway, aircraft, vessels, vehicle equipment, etc.] 

*  Antidisaster/crime-prevention equipment 
*  Burning appliances 
*  Electrothermal equipment 
*   Amusement facilities 
*  Facilities/applications associated directly with billing 

(3)  Supply systems such as electricity/gas/water supply systems, large-scale communication systems, and traffic/air traffic control 

systems requiring high reliability 

(4)  Facilities that are to comply with regulations of governmental/public agencies or specific industries 
(5)  Machinery or equipment that may affect human lives, human bodies or properties 
(6)  Other machinery or equipment equivalent to those set forth in items (1) to (5) above which require high reliability and safety 

4.  Precautions against long-term use 

Use of Azbil Corporation’s products, including switches, which contain electronic components, over a prolonged period may degrade 
insulation or increase contact-resistance  and may result in heat generation or any other similar problem causing such product or switch 
to develop safety hazards such as smoking, ignition, and electrification. Although acceleration of the above situation varies depending 
on the conditions or environment of use of the products, you are required not to use any  Azbil Corporation’s products for a period 
exceeding ten (10) years unless otherwise stated in specifications or instruction manuals. 

5.  Recommendation for renewal

Mechanical components, such as relays and switches, used for Azbil Corporation’s products will reach the end of their life due to wear by 
repetitious open/close operations.  
In addition, electronic components such as electrolytic capacitors will reach the end of their life due to aged deterioration based on 
the conditions or environment in which such electronic components are used. Although acceleration of the above situation varies 
depending on the conditions or environment of use, the number of open/close operations of relays, etc.  as prescribed in specifications 
or instruction manuals, or depending on the design margin of your machine or equipment, you are required to renew any Azbil 
Corporation’s products every 5 to 10 years unless otherwise specified in specifications or instruction manuals.  System products, field 
instruments (sensors such as pressure/flow/level sensors, regulating valves, etc.) will reach the end of their life due to aged deterioration 
of parts.  For those parts that will reach the end of their life due to aged deterioration, recommended replacement cycles are prescribed. 
You are required to replace parts based on such recommended replacement cycles. 

6.  Other precautions

Prior to your use of Azbil Corporation’s products, you are required to understand and comply with specifications (e.g., conditions and 
environment of use), precautions, warnings/cautions/notices as set forth in the technical documents prepared for individual Azbil 
Corporation’s products, such as catalogs, specifications, and instruction manuals to ensure the quality, reliability, and safety of those 
products. 

7.  Changes to specifications 

Please note that the descriptions contained in any documents provided by azbil are subject to change without notice for improvement 
or for any other reason.  For inquires or information on specifications as you may need to check, please contact our branch offices or 
sales offices, or your local sales agents. 

8.  Discontinuance of the supply of products/parts

Please note that the production of any Azbil Corporation’s product may be discontinued without notice. After manufacturing is 
discontinued, we may not be able to provide replacement products even within the warranty period.  
For repairable products, we will, in principle, undertake repairs for five (5) years after the discontinuance of those products. In 
some cases, however, we cannot undertake such repairs for reasons, such as the absence of repair parts.  For system products, field 
instruments,  we may not be able to undertake parts replacement for similar reasons. 

9.  Scope of services 

Prices of Azbil Corporation’s products do not include any charges for services such as engineer dispatch service. Accordingly, a separate 
fee will be charged in any  of the following cases: 

(1)  Installation, adjustment, guidance, and attendance at a test run 
(2)  Maintenance, inspection, adjustment, and repair
(3)  Technical guidance and technical education 
(4)  Special test or special inspection of a product under the conditions specified by you

Please note that we cannot provide any services as set forth above in a nuclear energy controlled area (radiation controlled area) or at a 
place where the level of exposure to radiation is equivalent to that in a nuclear energy controlled area. 

 AAS-511A-014-10

Содержание KFDB

Страница 1: ...OM2 6220 0000 Field Mounted Indicating Controller Model KFDB KFKB KFLB User s Manual...

Страница 2: ...s for a particular purpose and makes no express warranty except as may be stated in its written agreement with and for its customer In no event shall Azbil Corporation be liable to anyone for any indi...

Страница 3: ...ve 16 Chapter 4 CALIBRATION AND ADJUSTMENT OF TRANSMITTER SECTION 17 4 1 General 17 4 2 Calibration of Differential Pressure Transmitter 17 4 3 Calibration of Gauge Pressure Transmitter 19 4 4 Calibra...

Страница 4: ......

Страница 5: ...instrument can be converted to measure a flow differential pressure liquid level or pressure simply by changing the detector elements 1 2 Structure Mechanically the instrument consists of a detector...

Страница 6: ...sure Flange type Remote sealed type High working pressure type KFDB11 22 KFDB33 KFDB44 KFDB61 62 KFDB71 72 KFDB81 82 OM2 5220 1100 Pressure High pressure Low pressure Absolute pressure Remote sealed t...

Страница 7: ...3 Fig 1 2 Layout of Internal Components...

Страница 8: ...tial gap P external reset or PD external reset Proportional Band P 5 to 500 direct or reverse action Integral Time I 0 05 to 30 minutes Derivative Time D 0 05 to 30 minutes Differential Gap Adjustable...

Страница 9: ...ight JIS F 8001 Class 3 splash proof NEMA 3 IEC IP 54 Materials Case Aluminium diecast Cover Glass fiber reinforced polyester resin Finish Baked acryl paint corrosion resistant paint and silver paint...

Страница 10: ...l is converted into force by the feedback bellows and vector component F1 is fed back to the beam via the strap as shown in Fig 1 3 thereby making up a feedback loop which brings the beam into equilib...

Страница 11: ...splacement to drive the meter pointer At the same time the mechanism provides another deviation signal which is fed to the controller mechanism which renders proportional integral and or derivative ac...

Страница 12: ...lapper pin which is linked with the feedback link to change the gap between the nozzle and flapper thereby changing the nozzle back pressure The nozzle back pressure is amplified by the pilot relay to...

Страница 13: ...e restriction and capacity chamber of the integral unit in order to provide an integral I action By adding the deriva tive unit a derivative D action can be attained A derivative bellows is provided i...

Страница 14: ...d by replacing the feedback chamber of the proportional unit with a spring and feeding the output pressure of the pilot relay to the integral chamber The differential gap width is adjustable for a ran...

Страница 15: ...tic control output pressure of the controller As you press the check button the gauge indicates the pressure regulator output manual loading pressure When in the MAN mode the transfer lever set in the...

Страница 16: ...ceives an external pneumatic pressure setting signal 20 to 100 kPa 0 2 to 1 0 kgf cm2 and converts it into mechanical displacement which is fed via the overtravel link to the deviation generating mech...

Страница 17: ...e and from mechanical vibration 2 2 Air Supply The air supply must be dry and clean 2 3 Air Connection Ports The air connection ports are provided at lower sections of the controller and are of a Rc 1...

Страница 18: ...14...

Страница 19: ...the process to be controlled 3 3 Instrument With Manual Loader 3 3 1 Manual Operation First stabilize the process by manual operation Set the A M Selector lever to the M position and adjust the press...

Страница 20: ...that the pneumatic controller output signal increases and saturates Proportional band P PROP BAND dial at 50 Integral time I RESET dial at 0 05 minutes 3 Set the output pressure at the desired batch s...

Страница 21: ...of the instrument 4 2 Calibration of Differential Pressure Transmitter 1 Release the low pressure connection port marked L to atmosphere 2 Connect to the high pressure connection port marked H a varia...

Страница 22: ...comes 100 1 4 4 99 If the output is lower than 100 turn the boss so that the output becomes higher than 100 by an amount of 1 4 of the shift For example if the output is 98 turn the boss so that the o...

Страница 23: ...higher than 100 turn the boss so that the output becomes lower than 100 by an amount of 1 4 of the shift For example if the output is 104 turn the boss so that the output becomes 100 1 4 4 99 If the...

Страница 24: ...ube using a thread or fine wire looped into two circlets 4 5 1 Calibration Formula and procedure for Liquid Level Transmission 1 To calculate the weight buoyancy for calibration use the following form...

Страница 25: ...ss so that the output becomes lower than 100 by an amount of 1 4 of the shift For example if the output is 104 turn the boss so that the output becomes 100 1 4 4 99 If the output is lower than 100 tur...

Страница 26: ...b Calibration weight F corresponding to buoyancy F D2 H H L 4 1 D2 H H L where H High limit of specific gravity range 4 5 4 Adjustment of Stopper 1 When the instrument is shipped from the factory the...

Страница 27: ...23...

Страница 28: ...24...

Страница 29: ...se type of instrument 3 Inset the adjustment pin 1 2 mm dia through the adjustment pin hole 4 If the SP pointer has not been accurately aligned with the PV pointer align it accurately by means of the...

Страница 30: ...y 59 1 kPa 443 mmHg is sealed in the integral chamber of the controller Since this pressure may vary if the controller is left in this state for a prolonged period of time perform the above procedures...

Страница 31: ...kPa 300 mmHg by adjusting the PV input d Change the integral reset and derivative rate dials to the fully closed state 30 minutes or more e Balance the controller output pressure at 80 kPa 600 mmHg b...

Страница 32: ...ustment in a similar manner as in the case of 1 3 Adjust the length of the deviation link so that the deviations read in 1 and 2 become identical values but in reverse directions The length becomes sh...

Страница 33: ...es of angle Turning the pin clockwise set the pin groove horizontally at the side that the link falls 2 Set the setpoint at 50 Set the differential gap setting dial at the minimum 0 position of the IN...

Страница 34: ...oint as follows a Connect the instrument output OUT connection port a pressure gauge of Class 0 5 better b Set the proportional band setting dial of the controller mechanism to the INC MEAS DEC OUT st...

Страница 35: ...pressure 20 to 100 kPa 0 2 to 1 0 kgf cm2 to the ESP connection port of the instrument Fig 6 1 1 Zero Adjustment Apply 0 input and adjust the ZERO ADJ knob of the travel link so that the PV pointer i...

Страница 36: ...t knob If the error is in the positive side of the scale shorten the travel link turn the knob counterclockwise as viewed from the instrument bottom c The zero point also will vary as the travel link...

Страница 37: ...the stained filters Clean the dirty restrictions using a needle wire of 0 12 mm diameter 7 2 Controller Unit 1 Turn off the air supply and remove the deviation link 2 Remove the four screws of the bas...

Страница 38: ...32 Fig 7 2 Maintenance of Controller Unit...

Страница 39: ...HOUSING 1 4 GUIDE PIN 6 5 CONICAL SPRING 1 6 WASHER 1 7 SPRING 1 8 NOZZLE 1 9 WASHER 1 10 SEAL 1 11 DIAPHRAGM LOWER 1 12 EXHAUST RING OUTER 1 13 EXHAUST RING INNER 1 14 AREA PLATE 1 15 WASHER 1 16 DIA...

Страница 40: ...on 3 3 2 Apply a deviation in the direction that the AUTO output is decreased Turn the SP knob so that SP is smaller than PV when in the reverse action or SP is greater than PV when in the direct acti...

Страница 41: ...y and inspect diaphragm If leak is found replace diaphragm Controller output pressure is too high Nozzle of controller unit is clogged Clean the nozzle Stained valve seat of pilot relay Take out pilot...

Страница 42: ...36 Pneumatic Circuit Diagram...

Страница 43: ......

Страница 44: ...o your use 3 Measures to be taken to secure the required level of the reliability and safety of your Equipment in your use Although azbil is constantly making efforts to improve the quality and reliab...

Страница 45: ...argin of your machine or equipment you are required to renew any Azbil Corporation s products every 5 to 10 years unless otherwise specified in specifications or instruction manuals System products fi...

Страница 46: ......

Страница 47: ...Document Number OM2 6220 0000 Document Name Field Mounted Indicating Controller Model KFDB KFKB KFLB User s Manual Date 7th edition Jan 2020 Issued Edited by...

Страница 48: ......

Отзывы: