Azbil K1G Series Скачать руководство пользователя страница 30

Terms and Conditions

We would like to express our appreciation for your purchase and use of Azbil Corporation's products. 

You are required to acknowledge and agree upon the following terms and conditions for your purchase of Azbil Corporation's 

products (system products, field instruments, control valves, and control products), unless otherwise stated in any separate 

document, including, without limitation, estimation sheets, written agreements, catalogs, specifications and instruction manuals. 

1.  Warranty period and warranty scope

1.1  Warranty period

Azbil Corporation's products shall be warranted for one (1) year from the date of your purchase of the said products or 

the delivery of the said products to a place designated by you.

1.2  Warranty scope

In the event that Azbil Corporation's product has any failure attributable to azbil during the aforementioned warranty 

period, Azbil Corporation shall, without charge, deliver a replacement for the said product to the place where you 

purchased, or repair the said product and deliver it to the aforementioned place. 

Notwithstanding the foregoing, any failure falling under one of the following shall not be covered under this warranty: 

(1)  Failure caused by your improper use of azbil product  

(noncompliance with conditions, environment of use, precautions, etc. set forth in catalogs, specifications, 

instruction manuals, etc.); 

(2)  Failure caused for other reasons than Azbil Corporation's product;

(3)  Failure caused by any modification or repair made by any person other than Azbil Corporation or Azbil 

Corporation's subcontractors;  

(4)  Failure caused by your use of Azbil Corporation's product in a manner not conforming to the intended usage of 

that product; 

(5)  Failure that the state-of-the-art at the time of Azbil Corporation's shipment did not allow Azbil Corporation to 

predict; or 

(6)  Failure that arose from any reason not attributable to Azbil Corporation, including, without limitation, acts of God, 

disasters, and actions taken by a third party. 

Please note that the term “warranty” as used herein refers to equipment-only-warranty, and Azbil Corporation shall not 

be liable for any damages, including direct, indirect, special, incidental or consequential damages in connection with or 

arising out of Azbil Corporation's products. 

2.  Ascertainment of suitability 

You are required to ascertain the suitability of Azbil Corporation's product in case of your use of the same with your 

machinery, equipment, etc. (hereinafter referred to as “Equipment”) on your own responsibility, taking the following 

matters into consideration: 

(1)  Regulations and standards or laws that your Equipment is to comply with.

(2)  Examples of application described in any documents provided by Azbil Corporation are for your reference 

purpose only, and you are required to check the functions and safety of your Equipment prior to your use. 

(3)  Measures to be taken to secure the required level of the reliability and safety of your Equipment in your use 

Although azbil is constantly making efforts to improve the quality and reliability of Azbil Corporation's 

products, there exists a possibility that parts and machinery may break down. 

You are required to provide your Equipment with safety design such as fool-proof design, *1 and fail-safe 

design*2 (anti-flame propagation design, etc.), whereby preventing any occurrence of physical injuries, fires, 

significant damage, and so forth. Furthermore, fault avoidance, *3 fault tolerance,*4 or the like should be 

incorporated so that the said Equipment can satisfy the level of reliability and safety required for your use. 

*1. A design that is safe even if the user makes an error. 

*2. A design that is safe even if the device fails. 

*3. Avoidance of device failure by using highly reliable components, etc. 

*4. The use of redundancy. 

3.  Precautions and restrictions on application 

Azbil Corporation's products other than those explicitly specified as applicable (e.g. azbil Limit Switch For Nuclear Energy) 

shall not be used in a nuclear energy controlled area (radiation controlled area). 

Any Azbil Corporation's products shall not be used for/with medical equipment. 

The products are for industrial use. Do not allow general consumers to install or use any Azbil Corporation's product. 

However, azbil products can be incorporated into products used by general consumers. If you intend to use a product for 

that purpose, please contact one of our sales representatives. 

In addition, 

you are required to conduct a consultation with our sales representative and understand detail specifications, cautions 

for operation, and so forth by reference to catalogs, specifications, instruction manual, etc. in case that you intend to use 

azbil product for any purposes specified in (1) through (6) below. 

Moreover, you are required to provide your Equipment with fool-proof design, fail-safe design, anti-flame propagation 

design, fault avoidance, fault tolerance, and other kinds of protection/safety circuit design on your own responsibility to 

ensure reliability and safety, whereby preventing problems caused by failure or nonconformity. 

(1)  For use under such conditions or in such environments as not stated in technical documents, including catalogs, 

specification, and instruction manuals 

(2)  For use of specific purposes, such as: 

*   Nuclear energy/radiation related facilities  

[For use outside nuclear energy controlled areas] [For use of Azbil Corporation's Limit Switch For Nuclear 

Energy] 

*  Machinery or equipment for space/sea bottom 

*  Transportation equipment 

  [Railway, aircraft, vessels, vehicle equipment, etc.] 

*  Antidisaster/crime-prevention equipment 

Содержание K1G Series

Страница 1: ...It also provides necessary information for installation maintenance and troubleshooting This manual should be read by those who design and maintain equipment that uses this product Be sure to keep thi...

Страница 2: ...rable effort has been made to ensure that this manual is free from inaccuracies and omissions If you should find an error or omission please contact the azbil Group In no event is Azbil Corporation li...

Страница 3: ...ns listed below Handling Precautions Handling Precautions indicate items that the user should pay attention to when handling the K1G Series High Accuracy Position Sensor Note Notes indicate informatio...

Страница 4: ...n software for your equip ment that uses this device s serial communication function should read this man ual thoroughly K1G C04E K1G C04EG High Accuracy Position Sensor Controller User s Manual Manua...

Страница 5: ...tting switches 1 5 LED indicators 1 6 1 4 Displays 1 7 EtherCAT communication status check display 1 7 EtherCAT status display 1 8 Link status display 1 8 Chapter 2 Object Dictionary 2 1 2 1 Default P...

Страница 6: ......

Страница 7: ...me fieldbus system proposed and developed by Beckhoff Automation GmbH Germany Since it is based on Ethernet general purpose Ethernet cables can be used to establish a network EtherCAT is a registered...

Страница 8: ...Process data communication cycle 250 s min depends on the settings of the master device Mailbox communication CoE Synchronization method Freerun only distributed clocks is not supported LED indicators...

Страница 9: ...the setting that is being checked or changed 4 Display 2 Displays the measured value 5 Status indicators Indicate the operating status of the channel selected for display 1 Lit when the status of the...

Страница 10: ...ing between channels Used for tuning Cancels EPS filtering 9 Sensor head cable connector Connects the included sensor head cable and controller 10 Terminals Used for wiring of the power and input outp...

Страница 11: ...this K1G to the IN port of the slave device with a network cable Handling Precautions Do not use the EtherCAT communication network for other Ethernet communications ECAT ID setting switches Use these...

Страница 12: ...lash The device is in the Safe Operational state Process input data communication and mailbox communication are available On The device is in the Operational state Process input and output data commun...

Страница 13: ...r Global Model User s Manual CP SP 1397E EtherCAT status display Link status display EtherCAT communication status check display There are two modes for this display EtherCAT status display Display 1...

Страница 14: ...igit hexadecimal number Value range 0h to FFFFh decimal 0 to 65535 When not connected to EtherCAT 0h Handling Precautions The node address shown on this display is different from the ID specified by t...

Страница 15: ...0x1FFF Communication area 0x2000 to 0x5FFF Manufacturer specific area 0x6000 to 0xFFFF Profile specific area This device s objects such as measured value are mapped to the manufacturer specific area T...

Страница 16: ...1 0x07 0x3001 0x03 16 Event 2 0x08 0x3001 0x04 16 Event 3 0x09 0x3001 0x05 16 Event 4 0x0A 0x3002 0x01 16 Digital input 0x0B 0x3002 0x02 16 Digital output 0x0C 0x3003 0x01 16 Controller status 0x0D 0...

Страница 17: ...x00000000 Serial number 1 0x10F1 RECORD Error settings Not supported 2 0x01 UDINT RO 0x00000001 Local error reaction 0x02 UINT RO 0x0004 Sync error counter limit 0x1600 RECODE RxPDO transmit PDO defau...

Страница 18: ...time 0x0B UINT RO 0x0000 SM Event missed 0x0C UINT RO 0x0000 Cycle time too small 0x20 BOOL RO FALSE Sync error 0x1C33 RECODE Sync manager parameter to sync ch3 only Freerun is supported 0x01 UINT RO...

Страница 19: ...ct s subindex in a two digit hexadecimal number For subindex 0x00 the object code is described instead Object code The code of the object Data type The type of the object Access Read only RO or read a...

Страница 20: ...vent occurrence status Bit 0 Pass event occurrence Bit 1 Out event occurrence Bit 2 High event occurrence Bit 3 Low event occurrence Bit 4 EPS event occurrence Bit 5 Hold event occurrence Bit 6 Smudge...

Страница 21: ...1G Details on individual objects are given below Assignment Event occurrence Bit 0 DI1 ON 1 OFF 0 Bit 1 DI2 ON 1 OFF 0 Bit 2 DI3 ON 1 OFF 0 Bit 3 DI4 ON 1 OFF 0 Bit 4 15 No assignment always 0 Digital...

Страница 22: ...icates that the slave device is not ready for measuring Error status bit The error status of the controller Assignment Error status bit Bit 0 CPU in infinite loop Bit 1 FPGA malfunction Bit 2 ROM erro...

Страница 23: ...rx tx Comment 0x3100 RECORD Digital input 0x01 UINT RW rx Digital input Digital input The EtherCAT master device can send digital input commands to the K1G The result can be checked at 0x3002 01 Detai...

Страница 24: ...Memo...

Страница 25: ...The ESI file for the K1G C04E G can be downloaded from the website indicated below search for K1G Download product documents and EtherCAT ESI file Compo Club URL http www compoclub com EtherCAT ESI fi...

Страница 26: ...Memo...

Страница 27: ...G 1000 4 EtherCAT Specification Part 4 Data Link Layer Protocol Definition S R V 1 0 3 2013 01 21 ETG 1000 5 EtherCAT Specification Part 5 Application Layer Service Definition S R V 1 0 3 2013 01 21 E...

Страница 28: ...r device writes to a slave device CoE CAN application protocol over EtherCAT The CAN protocol over EtherCAT SDO Service data objects Objects for data exchange between master and slave ESC EtherCAT sla...

Страница 29: ...Revision History CP SP 1419E Printed Edn Revised pages Description June 2017 1...

Страница 30: ...documents provided by Azbil Corporation are for your reference purpose only and you are required to check the functions and safety of your Equipment prior to your use 3 Measures to be taken to secure...

Страница 31: ...struments sensors such as pressure flow level sensors regulating valves etc will reach the end of their life due to aged deterioration of parts For those parts that will reach the end of their life du...

Страница 32: ...1st edition June 2017 V...

Отзывы: