Azbil ATT082 Скачать руководство пользователя страница 28

Terms and Conditions

We would like to express our appreciation for your purchase and use of Azbil Corporation's products. You are required to 

acknowledge and agree upon the following terms and conditions for your purchase of Azbil Corporation's products (system 

products, field instruments, control valves, and control products), unless otherwise stated in any separate document, including, 

without limitation, estimation sheets, written agreements, catalogs, specifications and instruction manuals.

1.  Warranty period and warranty scope

1.1  Warranty period

Azbil Corporation's products shall be warranted for one (1) year from the date of your purchase of the said products or 

the delivery of the said products to a place designated by you.

1.2  Warranty scope

In the event that Azbil Corporation's product has any failure attributable to azbil during the aforementioned warranty period, 

Azbil Corporation shall, without charge, deliver a replacement for the said product to the place where you purchased, 

or repair the said product and deliver it to the aforementioned place. Notwithstanding the foregoing, any failure falling 

under one of the following shall not be covered under this warranty:

(1)  Failure caused by your improper use of azbil product  

(noncompliance with conditions, environment of use, precautions, etc. set forth in catalogs, specifications, 

instruction manuals, etc.);

(2)  Failure caused for other reasons than Azbil Corporation's product;

(3)  Failure caused by any modification or repair made by any person other than Azbil Corporation or Azbil Corporation's 

subcontractors;

(4)  Failure caused by your use of Azbil Corporation's product in a manner not conforming to the intended usage of 

that product;

(5)  Failure that the state-of-the-art at the time of Azbil Corporation's shipment did not allow Azbil Corporation to 

predict; or

(6)  Failure that arose from any reason not attributable to Azbil Corporation, including, without limitation, acts of God, 

disasters, and actions taken by a third party.

Please note that the term “warranty” as used herein refers to equipment-only-warranty, and Azbil Corporation shall not 

be liable for any damages, including direct, indirect, special, incidental or consequential damages in connection with or 

arising out of Azbil Corporation's products.

2.  Ascertainment of suitability

You are required to ascertain the suitability of Azbil Corporation's product in case of your use of the same with your 

machinery, equipment, etc. (hereinafter referred to as “Equipment”) on your own responsibility, taking the following 

matters into consideration:

(1)  Regulations and standards or laws that your Equipment is to comply with.

(2)  Examples of application described in any documents provided by Azbil Corporation are for your reference 

purpose only, and you are required to check the functions and safety of your Equipment prior to your use.

(3)  Measures to be taken to secure the required level of the reliability and safety of your Equipment in your use

Although azbil is constantly making efforts to improve the quality and reliability of Azbil Corporation's 

products, there exists a possibility that parts and machinery may break down.

You are required to provide your Equipment with safety design such as fool-proof design, 

*1

 and fail-safe 

design

*2

 (anti-flame propagation design, etc.), whereby preventing any occurrence of physical injuries, fires, 

significant damage, and so forth. Furthermore, fault avoidance, 

*3

 fault tolerance,

*4

 or the like should be 

incorporated so that the said Equipment can satisfy the level of reliability and safety required for your use.

*1. A design that is safe even if the user makes an error.

*2. A design that is safe even if the device fails.

*3. Avoidance of device failure by using highly reliable components, etc.

*4. The use of redundancy.

3.  Precautions and restrictions on application

Azbil Corporation's products other than those explicitly specified as applicable (e.g. azbil Limit Switch For Nuclear Energy) 

shall not be used in a nuclear energy controlled area (radiation controlled area).

Any Azbil Corporation's products shall not be used for/with medical equipment.

The products are for industrial use. Do not allow general consumers to install or use any Azbil Corporation's product. 

However, azbil products can be incorporated into products used by general consumers. If you intend to use a product for 

that purpose, please contact one of our sales representatives.

In addition,

you are required to conduct a consultation with our sales representative and understand detail specifications, cautions 

for operation, and so forth by reference to catalogs, specifications, instruction manual, etc. in case that you intend to use 

azbil product for any purposes specified in (1) through (6) below.

Moreover, you are required to provide your Equipment with fool-proof design, fail-safe design, anti-flame propagation 

design, fault avoidance, fault tolerance, and other kinds of protection/safety circuit design on your own responsibility to 

ensure reliability and safety, whereby preventing problems caused by failure or nonconformity.

(1)  For use under such conditions or in such environments as not stated in technical documents, including catalogs, 

specification, and instruction manuals

Содержание ATT082

Страница 1: ...CM2 ATT082 2002 ATT082 Temperature transmitter Brief User s Manual...

Страница 2: ...for its customer In no event shall Azbil Corporation be liable to anyone for any indirect special or consequential damages This information and specifications in this document are subject to change w...

Страница 3: ...als 7 3 4 CE mark Declaration of Conformity 8 3 5 HART Protocol Certification 8 3 6 Korea Certification Mark 8 Chapter 4 Installation instructions 9 4 1 Incoming acceptance transport storage 9 4 1 1 I...

Страница 4: ...elements 17 6 1 3 Local operation 18 6 2 Configuration of transmitter and HART protocol 18 Chapter 7 Commissioning 19 7 1 Post installation check 19 7 2 Switching on the transmitter 19 7 3 Enabling co...

Страница 5: ...ameplate You can use this Ex documentation if the two numbers i e in the Ex documentation and on the nameplate are identical 1 2 Safety Precautions for Use For safe use of the product the following sy...

Страница 6: ...stand on this unit Doing so may damage the device or cause injury Bumping the glass of the display with a tool may cause damage or injury Be careful Install the device correctly Incorrect or incomplet...

Страница 7: ...working on the vent check its direction so that people do not come into contact with vented gas There is a danger of burns or other physical harm When the device is being used in an explosion proof a...

Страница 8: ...4 Chapter 1 Important document information...

Страница 9: ...resistance and voltagetransmitters The head transmitter version of the device is intended for mounting in a flat faceterminal head as per DIN EN 50446 The manufacturer is not liable for damage caused...

Страница 10: ...6 Chapter 2 Basic safety instructions...

Страница 11: ...itter example Ex version 1 Power supply current consumption and extended order code 2 Serial number device revision and firmware version 3 Approvals with symbols 4 2 lines for the TAG name 5 Approval...

Страница 12: ...es The manufacturer confirms that the device is compliant with the relevant guidelines by applying the CE mark 3 5 HART Protocol Certification The temperature transmitter is registered by HART Communi...

Страница 13: ...mitter version with screw terminals Dimensions in mm in A Spring travel L 5 mm not for US M4 securing screws B Mounting elements for attachable measured value display C Interface for contacting measur...

Страница 14: ...uide the mounting screws 2 through the lateral bores of the head transmitter 3 3 Screw the head transmitter to the field housing 4 After wiring close the field housing cover 1 4 4 Post installation ch...

Страница 15: ...the terminal head or the field housing 2 Feed the cables through the opening in the cable gland 3 Connect the cables as shown in 5 1 4 Retighten the cable gland and close the housing cover In order to...

Страница 16: ...ments considerably The sensors must remain galvanically isolated from one another by con necting each sensor separately to a transmitter The transmitter provides sufficient galvanic isolation 2 kV AC...

Страница 17: ...unication Observe grounding concept of the plant Please also observe the general procedure on the page 10 1 2 1 2 3 4 Figure 5 2 Connecting the signal cables and power supply 1 Terminals for HART prot...

Страница 18: ...f disturbance variables as per NAMUR NE21 is thus guaranteed 1 2 3 4 Figure 5 3 Shielding and grounding the signal cable at one end with HART communication 1 Optional grounding of the field device iso...

Страница 19: ...11 to 42 V DC SIL mode U 11 to 32 V DC for the head transmitter or U 12 to 32 V DC for the DIN rail transmitter Do the cables have adequate strain relief Are the power supply and signal cables correc...

Страница 20: ...16 Chapter 5 Wiring...

Страница 21: ...PV I e g S1 for a measured value from channel 1 or DT for the device temperature 6 Configuration locked symbol The configuration locked symbol appears when configuration is locked via the hardware 7 S...

Страница 22: ...display onto the head transmitter in the correct position The head transmitter accepts the settings within one second 5 Secure the cover back onto the terminal head or field housing Switching write p...

Страница 23: ...stic events and the corresponding troubleshooting instructions can be found in the User s Manual The device is operational after approx 30 seconds and the plug in display after approx 33 seconds in no...

Страница 24: ...20 Chapter 7 Commissioning...

Страница 25: ...rinsically safe systems for Hazardous classified locations and the National Electrical Code ANSI NFPA 70 FM Approved Associated Apparatus must meet the following parameters Uo Ui Io Ii Po Pi Ca Ci Cca...

Страница 26: ...ed for appropriate area classification Class II use a dust tight seal Keep tight when circuits alive NONINCENDIVE NI Class I Div 2 Groups ABCD Depending on location install per National Electrical Cod...

Страница 27: ......

Страница 28: ...onsibility taking the following matters into consideration 1 Regulations and standards or laws that your Equipment is to comply with 2 Examples of application described in any documents provided by Az...

Страница 29: ...u are required to renew any Azbil Corporation s products every 5 to 10 years unless otherwise specified in specifications or instruction manuals System products field instruments sensors such as press...

Страница 30: ......

Страница 31: ...Document Number CM2 ATT082 2002 Document Name ATT082 Temperature transmitter Brief User s Manual Date 1st edition May 2015 2nd edition July 2016 Issued Edited by Azbil Corporation...

Страница 32: ......

Отзывы: