Safety Instructions 

Please read instructions carefully and use the product as specified in this manual. Be sure to keep this manual nearby for quick 
reference.  

Usage Restrictions 

This product is targeted for general air conditioning. Do not use this product in a situation where human life may be affected. If 
this product is used in a clean room or a place where reliability or control accuracy is particularly required, please contact our 
sales representative. Azbil Corporation will not bear any responsibility for the results produced by the operators. 

 

Warnings and Cautions 

 WARNING

 

Alerts users that improper handling may cause death or serious injury. 

 CAUTION

 

Alerts users that improper handling may cause minor injury or material loss. 

 

Signs 

 

Alerts users possible hazardous conditions caused by erroneous operation or erroneous use. The symbol inside I 
indicates the specific type of danger.  
(For example, the sign on the left warns of the risk of electric shock.) 

 

Notifies  users  that  specific  actions  are  prohibited  to  prevent  possible  danger.  The  symbol  inside  Q  graphically 
indicates the prohibited action.  
(For example, the sign on the left notifies that disassembly is prohibited.)  

 

Instructs users to carry out a specific obligatory action to prevent possible danger. The symbol inside d graphically 
indicates the actual action to be carried out.  
(For example, the sign on the left indicates general instructions.) 

 

  WARNING 

 

Before wiring or maintenance, be sure to turn off the power to the product. 
Failure to do so might cause electric shock or device failure. 

 

  CAUTION 

 

Install and use the product under the operating conditions requirement (temperature, humidity, power, vibration, 
shock, mounting direction, atmospheric condition, etc.) as listed in the specifications. 
Failure to do so might cause fire or device failure. 

 

Installation and wiring must be performed by qualified personnel in accordance with all applicable safety standards. 

 

All wiring must comply with applicable codes and ordinances. 

 

Take anti-lightening measures based on regional and building characteristics. 
Lightening might cause fire or critical damage to the products without the anti-lightening measures. 

 

If more than the rated power voltage is applied to the product, replace the product with new one for your safety. 
Failure to do so might cause device failure or overheating. 

 

Do not disassemble the product. 
Doing so might cause device failure. 

 

Dispose of the product as industrial waste in accordance with your local regulations. 
Do not reuse all or part of this product. 

Содержание ACTIVAL+

Страница 1: ...ve position at one time Installable 50 m away from Model FVY513_J FVY514_J FVY515_J Display panel is connected to Model FVY513_J FVY514_J FVY515_J with JIS VCTF cable 0 3 mm2 4 cores and max cable len...

Страница 2: ...ssembly is prohibited Instructs users to carry out a specific obligatory action to prevent possible danger The symbol inside d graphically indicates the actual action to be carried out For example the...

Страница 3: ...Coil inlet temperature C T2 Coil outlet temperature C HC Heat Cool E Error Opening Actual valve position in bar graph Flowrate Actual flow rate in bar graph Communication Transmission system AP bus RS...

Страница 4: ...igure 1 Outside dimensions mm Mounting dimensions of the base plate Figure 2 Mounting dimensions of the base plate mm 96 24 5 96 Base plate Case 48 48 33 15 66 15 51 5 Mounting holes Cable conduit Hoo...

Страница 5: ...AB 7043 5 Parts Identification Figure 3 Parts identification Hook to remove the case from the base plate Base plate Case Face plate Insertion guide female LCD Insertion guide male...

Страница 6: ...2 4 T1 Coil inlet temperature 10 0 to 99 9 C 5 T2 Coil outlet temperature 10 0 to 99 9 C Opening Valve position indicated in a bar graph 0 to 100 with every 10 increment Flowrate Flow indicated in a...

Страница 7: ...s button to go back to the analog values display screen Note No button operation for continuous 10 minutes on the parameter setting screen will automatically switch from the parameter setting screen t...

Страница 8: ...ripped lead wires to each terminal Terminals arrangement Figure 7 Sheath strip length Terminal number Type Lead wire color 1 12 V DC Red RED 2 0 V Black BLK 3 AP bus White WHT 4 AP bus Green GRN Note...

Страница 9: ...ate terminals out of the base plate through the base plate conduit on the bottom right and mount the base plate on the mounting location with the two M4 tapping screws accessory of Display Panel Figur...

Страница 10: ...is generally installed on a visible position such as on a wall in a machine room or on a control panel cabinet However it may possibly be installed outdoors or in a ceiling In such a case install the...

Страница 11: ...VY513_J FVY514_J FVY515_J To connect the cable to Model FVY513_J FVY514_J FVY515_J refer to Specification Installation of Model FVY513_J FVY514_J FVY515_J AB 7408 ACTIVAL Modbus Protocol Model PN16 EN...

Страница 12: ...cations are subject to change without notice Building Systems Company http www azbil com Rev 6 0 Mar 2018 AB 7043 J AI 7043 Rev 2 2 12 This product complies with the following harmonised standards of...

Отзывы: