34
Frost 1wheelEr
(Frost 1wheel - error) This message will appear after the reset of the fixture if the head’s
magnetic-indexing circuit malfunctions (sensor failed or magnet missing) or the steppermotor is
defective (or its driving IC on the main PCB)
.
TheFrost 1 - movement is not located in the default
position after the reset
.
Frost 2wheelEr
(Frost 2wheel - error) This message will appear after the reset of the fixture if the head’s
magnetic-indexing circuit malfunctions (sensor failed or magnet missing) or the steppermotor is
defective (or its driving IC on the main PCB)
.
The Frost 2 - movement is not located in the
default position after the reset
.
Animation_RotwheelEr
(Animation_Rotwheel - error) This message will appear after the reset of the fixture if the head’s
magnetic-indexing circuit malfunctions (sensor failed or magnet missing) or the steppermotor is
defective (or its driving IC on the main PCB)
.
The Animation_Rot - movement is not located in
the default position after the reset
.
12. CLEANING AND MAINTENANCE
The following points have to be considered during inspection
1) All screws for installing the devices or parts of the device have to be tightly connected and
must not be corroded
.
2) There must not be any deformations to the housing
lenses
rigging and installation points
(ceiling
suspension
trussing)
.
3) Motorized parts must not show any signs of wear and must move smoothly without issue
.
4) The power supply cables must not show any damage
material fatigue or sediment
.
Further instructions depending on the installation location and usage have to be adhered to by a
qualified installer and any safety concerns have to be removed
.
In order to ensure the device remains in good condition and does not fail prematurely we suggest
regular maintenance
.
1) Clean the inside and outside lens each week to avoid loss of output due to accumulation of
dust/ dirt on the lens
.
2) Clean the fans each week to ensure maximum airflow and efficient thermal cooling
.
This will
ensure the light source is operated in the best possible condition
.
3) A detailed electrical check by an approved electrician everyquarter to make sure that the
circuit contacts are in good condition
.
This will prevent poor circuit contacts and the resultant
overheating
.
Содержание Mistral S
Страница 1: ...Manuel d utilisation KEEP THIS MANUAL FOR FUTURE NEEDS...
Страница 8: ...7 4 DIMENSIONAL DRAWINGS 4 1 Fixture Dimension...
Страница 9: ...8 4 2 Gobo Filter Dimension 4 3 Color Filter Dimension...
Страница 10: ...9 4 4 Animation Dimension...