manualshive.com logo in svg
background image

Avoid touching the lenses with your bare fingers, to prevent fingerprints on the optics.

Check-up

To prevent dangerous situations, make sure your fixture is in optimal condition before using it. Check your 
fixture frequently, using the following check list:
- All screws must be mounted tightly. 
- Check all screws and metal parts for corrosion. There shouldn't be any visible signs of corrosion.
- The exterior of your fixture must be in optimal condition. Check your fixture for dents, cracks or missing 
parts. 
- Your installation spot must be in optimal condition. Check your installation spot for corrosion, cracks, dents 
and strength.
- Electrical components (connectors and cables) must be in optimal condition. No form of damage (cuts, 
exposed wire cores or any other irregularities) should be visible.

If any visual or mechanical damage is detected, contact your local dealer or a specialised technician. Do not 
use a damaged or malfunctioning fixture.

Transport and storage

The ComPar 2 can be transported directly after shutdown. As the ComPar 2's light sources do not need time 
to cool down, the device can be stored and transported instantly.

During transport, the device must be securely protected to ensure it stays reliable and in optimal shape. 
Always use the original box and packaging material to transport the unit, or a fitting flight case or flight bag if 
the device is transported frequently for mobile use. 

Power input and output

The ComPar 2 is equipped with an extra power output, which allows for daisy-chaining of several light 
effects. 

The output of the ComPar 2 can handle a maximum power of 2,000 W. This equals around 8.9 A based on a 
230V AC, 50Hz connection. A maximum of 100 ComPar 2 fixtures can be daisy-chained from the main 
ComPar 2 device. 

Please make sure that no equipment with a power consumption higher than 2,000 W is connected to the 
output of the ComPar 2. The IEC C13/C14 chassis connectors can only withstand a maximum current of 10 
A at 230 V AC, 50 Hz and the included power cable has cores of only 3x 1 mm². If you use a higher current, 
there is a chance of melting connectors and/or cables. Ayra cannot be held responsible for any damage 
and/or injuries caused by improper use of the power outlets.

If you want to connect more than 100 ComPar 2 fixtures or larger equipment, the connection to a power 
outlet must be renewed. 

Please note that the IEC C13/C14 connectors are not 'hot-swappable'. This means that the connectors may 
not be pulled out of the chassis if the cable is still connected to a power output socket. 

The ComPar 2 is equipped with a fuse for its own components. The device's power input is directly linked to 
the device's power output. 

XLR input and output

The ComPar 2 is equipped with XLR chassis connectors. The DMX input is usually connected with a XLR 
cable that has a locking mechanism so it cannot be pulled from the chassis easily. Usually the locking part 
has to be pressed and held to unlock the mechanism. When doing this, the connector can be removed from 
its socket.

Remote: 

The ComPar 2 uses a CR2025 battery for the remote control. A battery is included upon delivery. A protective
sheet of transparent plastic sticks out of the bottom of the unit. When it's removed, contact is made between 
the remote PCB and battery, and the remote can be used to control the ComPar 2. 

All information and illustrations shown in this user manual are subject to change without further notice.

User manual version: 1.0

Creation date + author initials: 04-11-2015 RV Revision date + author initials: 

Содержание 9000-0021-6276

Страница 1: ...h remote control User manual All information and illustrations shown in this user manual are subject to change without further notice User manual version 1 0 Creation date author initials 04 11 2015 R...

Страница 2: ...or menu buttons The ComPar 2 has a wide range of built in colour presets as well as colour fade jump options DMX and master slave options are also available As the ComPar 2 s SMD LEDs deliver a wide...

Страница 3: ...do not modify any hardware or software Do not insert objects into the air vents of this device Do not connect this device to a dimmer pack Do not switch the system on and off frequently as this will r...

Страница 4: ...a power outlet with the wrong type of voltage or using the product with a wrong type of power supply may cause permanent damage to the device Avoid shocks and collisions during use and transport Do no...

Страница 5: ...ttention CAUTION Danger of explosion if battery is incorrectly replaced Replace only with the same or equivalent type of battery Do not expose batteries to excessive heat such as sunshine fire and the...

Страница 6: ...ur environment from being polluted CE The CE mark indicates that the product complies with applicable European directives and regulations Indoor use only This device is designed to be used indoors onl...

Страница 7: ...r a longer period of time disconnect it from the power supply and store it in a dust free environment Always check the unit for possible damage before use If you suspect that something is wrong with t...

Страница 8: ...Speed Brightness FL Flash Strobe R Red intensity G Green intensity B Blue intensity W White intensity not available on this product A Amber intensity not available on this product JU Colour jump FA Co...

Страница 9: ...COL7 Colour preset RGBW CR00 CR99 Dimmer red CG00 CG99 Dimmer green CB00 CB99 Dimmer blue CF00 CF99 Flash speed strobe speed JUMP JU00 JU99 Colour jump speed JF00 JF99 Flash speed strobe speed FADE F...

Страница 10: ...o increase the sensitivity making sure that the fixture responds to the sound accurately The sensitivity can be adjusted from 0 to 100 100 being the most sensitive LED LED display on off If you use th...

Страница 11: ...f the first fixture The master slave function requires 3p XLR male XLR female cables not included Connect the DMX output of the master fixture to the DMX input of the second fixture and from this fixt...

Страница 12: ...s 1 Dimmer 0 100 000 255 2 Strobe slow fast 000 255 3 Red 0 100 000 255 4 Green 0 100 000 255 5 Blue 0 100 000 255 6 Colour preset 000 036 Colour 1 037 073 Colour 2 074 110 Colour 3 111 147 Colour 4 1...

Страница 13: ...es 54 powerful SMD RGB LEDs to create an immense number of colours The light source cannot be replaced by the user The device does not require cool down time after use before it is transported The Com...

Страница 14: ...n A maximum of 100 ComPar 2 fixtures can be daisy chained from the main ComPar 2 device Please make sure that no equipment with a power consumption higher than 2 000 W is connected to the output of th...

Страница 15: ...se or DMX activity signal LEDs active Check your DMX cables for possible connector breaks and replace them if necessary Wrong operating mode Switch the operating mode of the device to DMX mode The fix...

Страница 16: ...peration as Slave it is not possible to activate the automatic or music controlled modes Remote control does not work Aimed wrong The IR receiver of the device is placed on the front panel of the devi...

Страница 17: ...ur preset custom colour colour jump colour fade sound controlled operation adjustable sound sensitivity master slave operating mode Technical info connection voltage 100 240V AC 50 60 Hz fuse F3AL250V...