Installation and connection requirements

The Ayra ComPar 2 is a versatile product that can be used in many ways. To use this device as intended and
to be sure that it is used in a safe way, the following requirements must be met during the setup, installation 
and connection.

Installing the system in a standing position

The ComPar 2 is used for lots of applications and can be placed directly on a flat surface such as a table, 
floor or counter. Please ensure that the device is positioned safely and the power cord is installed properly. 
Accidents may happen if the power cord is hanging freely and can be pulled by small children, causing the 
device to fall down. Install the device securely and contact your local dealer or a skilled technician for the 
best installation advice for permanent and mobile setups. 

The device can be placed in a standing position for uplighting purposes, using either the integrated double 
bracket or the rubber feet. 

Installing the fixture in a suspended position

The ComPar 2 is equipped with a mounting bracket that makes it possible to install the device suspended 
from a ceiling, wall or beam. Mounting hardware is not included, but available at your local hardware store. 
Please make sure to select the right mounting hardware for the material. For example, wooden beams 
require other hardware than a brick wall. 

A safety cable must be used to secure the device if the device is installed in a suspended position. A safety 
cable is not included, but can be purchased at your local dealer. The bracket knobs will hold the fixture if it 
falls, so looping the safety cable through the mounting bracket is sufficient. If the mounting hardware should 
fail for any reason, the device must not be permitted to fall more than 30 cm and the safety cable must be 
able to carry 10x the weight of the unit. 

Light source

The ComPar 2 uses 54 powerful SMD RGB LEDs to create an immense number of colours. The light source 
cannot be replaced by the user. The device does not require cool down time after use before it is 
transported. The ComPar 2 uses convection cooling and is not equipped with cooling fans. If the device is 
used in a fixed installation, it can be disconnected from the power source or turned off. There are no fans 
installed to cool the lamp, so a standby setting before shutdown is not required.

Do not look at the device's light source from short distance when it is in use. The human eye will adjust to the
bright beams and possibly create temporary blind spots. These will disappear after a short period of time and
will not cause permanent damage to the eye or permanent loss of vision, but can cause disorientation and 
inconvenience.

To protect the user and the device from damage and/or injury, a plastic lens is placed in front of the SMD 
LEDs. It is therefore not possible to actually touch the SMD LEDs. The PCB it is soldered on for your 
protection. If the lens is severely damaged or grants direct access to the PCB for any reason, the device 
should not be used and disconnected from the mains. 

Spare parts

This unit has no user-serviceable parts inside. If internal components sustain damage, contact your local 
dealer or a specialised technician in order to repair the fixture.

Cleaning: 

Clean the housing of the fixture frequently with a damp cloth, to remove dust and/or dirt. 

WARNING: 

Always disconnect the fixture from your wall outlet or other power supply and let the fixture dry 

before reconnecting it. This prevents possible electric shocks.

The lenses can be cleaned with a non-aggressive glass cleaning solution, but this is not recommended. Ayra
advises cleaning the mirror and lens with a fine brush, while removing dust and/or dirt with a vacuum cleaner.

All information and illustrations shown in this user manual are subject to change without further notice.

User manual version: 1.0

Creation date + author initials: 04-11-2015 RV Revision date + author initials: 

Содержание 9000-0021-6276

Страница 1: ...h remote control User manual All information and illustrations shown in this user manual are subject to change without further notice User manual version 1 0 Creation date author initials 04 11 2015 R...

Страница 2: ...or menu buttons The ComPar 2 has a wide range of built in colour presets as well as colour fade jump options DMX and master slave options are also available As the ComPar 2 s SMD LEDs deliver a wide...

Страница 3: ...do not modify any hardware or software Do not insert objects into the air vents of this device Do not connect this device to a dimmer pack Do not switch the system on and off frequently as this will r...

Страница 4: ...a power outlet with the wrong type of voltage or using the product with a wrong type of power supply may cause permanent damage to the device Avoid shocks and collisions during use and transport Do no...

Страница 5: ...ttention CAUTION Danger of explosion if battery is incorrectly replaced Replace only with the same or equivalent type of battery Do not expose batteries to excessive heat such as sunshine fire and the...

Страница 6: ...ur environment from being polluted CE The CE mark indicates that the product complies with applicable European directives and regulations Indoor use only This device is designed to be used indoors onl...

Страница 7: ...r a longer period of time disconnect it from the power supply and store it in a dust free environment Always check the unit for possible damage before use If you suspect that something is wrong with t...

Страница 8: ...Speed Brightness FL Flash Strobe R Red intensity G Green intensity B Blue intensity W White intensity not available on this product A Amber intensity not available on this product JU Colour jump FA Co...

Страница 9: ...COL7 Colour preset RGBW CR00 CR99 Dimmer red CG00 CG99 Dimmer green CB00 CB99 Dimmer blue CF00 CF99 Flash speed strobe speed JUMP JU00 JU99 Colour jump speed JF00 JF99 Flash speed strobe speed FADE F...

Страница 10: ...o increase the sensitivity making sure that the fixture responds to the sound accurately The sensitivity can be adjusted from 0 to 100 100 being the most sensitive LED LED display on off If you use th...

Страница 11: ...f the first fixture The master slave function requires 3p XLR male XLR female cables not included Connect the DMX output of the master fixture to the DMX input of the second fixture and from this fixt...

Страница 12: ...s 1 Dimmer 0 100 000 255 2 Strobe slow fast 000 255 3 Red 0 100 000 255 4 Green 0 100 000 255 5 Blue 0 100 000 255 6 Colour preset 000 036 Colour 1 037 073 Colour 2 074 110 Colour 3 111 147 Colour 4 1...

Страница 13: ...es 54 powerful SMD RGB LEDs to create an immense number of colours The light source cannot be replaced by the user The device does not require cool down time after use before it is transported The Com...

Страница 14: ...n A maximum of 100 ComPar 2 fixtures can be daisy chained from the main ComPar 2 device Please make sure that no equipment with a power consumption higher than 2 000 W is connected to the output of th...

Страница 15: ...se or DMX activity signal LEDs active Check your DMX cables for possible connector breaks and replace them if necessary Wrong operating mode Switch the operating mode of the device to DMX mode The fix...

Страница 16: ...peration as Slave it is not possible to activate the automatic or music controlled modes Remote control does not work Aimed wrong The IR receiver of the device is placed on the front panel of the devi...

Страница 17: ...ur preset custom colour colour jump colour fade sound controlled operation adjustable sound sensitivity master slave operating mode Technical info connection voltage 100 240V AC 50 60 Hz fuse F3AL250V...

Отзывы: