manualshive.com logo in svg
background image

Setting up the unit

To activate the unit, use the included power cable to connect it to a suitable 230V, 50Hz power outlet. 

The device will need a few seconds to start up and will continue in the previously used mode. If that is the 
DMX mode and no signal is detected, the fixture will switch to the last selected stand-alone mode. 

The device can now be set as desired, using the menu display or the included remote control. The remote 
control allows you to control the ComPar 2 when it's set to stand-alone mode, or when it's connected in a 
master-slave setup. This way, standard colour presets, colour fades, sound-controlled modes, etc. can be 
selected. 

If you need additional options, the menu display and buttons can be used to select the right settings. 

Use the display and the menu buttons underneath to set preferences, change settings and scroll through the 
menu. “Enter” is used to save a certain setting or preset. Press “Menu” for at least 2 seconds to return to the 
main menu. 
The table below explains each feature and value. 

display

Mode

Function

ADDR

DMX address setting

Address 001 … 512

CHND

DMX channel mode

2CH – 2 Channel mode
3CH1 – 3 Channel mode RGB
3CH2 – 3 Channel mode dimmer, strobe, macro
6CH – 6 Channel mode

SLND

Slave mode

Master: Master unit
Slave: Slave unit (follows master commands)

SHND

Show modes

COLO

COL1 – COL7: Colour preset

RGBW:

CR00 – CR99: Dimmer red
CG00 – CG99: Dimmer green
CB00 – CB99: Dimmer blue
CF00 – CF99: Flash speed (strobe speed)

JUMP

JU00 – JU99: Colour jump speed
JF00 – JF99: Flash speed (strobe speed)

FADE

FA00 – FA99: Colour fade speed
FF00 – FF99: Flash speed (strobe speed)

SHOW

Sound-controlled operation

SOUN

Sound mode on/off

ON/OFF: Switch sound sensitivity on or off

SENS

Sound sensitivity

00 – 99: Sound sensitivity in %

BALA

Colour balance

RED: Red correction 000 – 255
GREE: Green correction 000 – 255
BLUE: Blue correction 000 - 255

LED

ON/OFF

LED display on/off when not in use

DISP

Dlsp / dslp

Display flip

TEST

Test mode

Easy way of checking LEDs during maintenance

HOUR

Working hours

0000 – 9999 working hours

VER

Firmware version

Shows firmware version

ADDR: 

DMX address setting, used to determine the DMX starting channel. Starting with the selected 

channel, the fixture will respond to values corresponding with the number of used channels. (For example, if 
you set the starting address to value 003, the fixture will respond to channels 3, 4, 5, etc.)

CHND: 

The fixture's channel mode makes it possible to select the right channel mode setting for each 

application. For simple and basic setups, users may prefer to use the 2CH mode. For advanced setups, 
users may prefer to choose the 6CH mode to be able to control every feature.

All information and illustrations shown in this user manual are subject to change without further notice.

User manual version: 1.0

Creation date + author initials: 04-11-2015 RV Revision date + author initials: 

Содержание 9000-0021-6276

Страница 1: ...h remote control User manual All information and illustrations shown in this user manual are subject to change without further notice User manual version 1 0 Creation date author initials 04 11 2015 R...

Страница 2: ...or menu buttons The ComPar 2 has a wide range of built in colour presets as well as colour fade jump options DMX and master slave options are also available As the ComPar 2 s SMD LEDs deliver a wide...

Страница 3: ...do not modify any hardware or software Do not insert objects into the air vents of this device Do not connect this device to a dimmer pack Do not switch the system on and off frequently as this will r...

Страница 4: ...a power outlet with the wrong type of voltage or using the product with a wrong type of power supply may cause permanent damage to the device Avoid shocks and collisions during use and transport Do no...

Страница 5: ...ttention CAUTION Danger of explosion if battery is incorrectly replaced Replace only with the same or equivalent type of battery Do not expose batteries to excessive heat such as sunshine fire and the...

Страница 6: ...ur environment from being polluted CE The CE mark indicates that the product complies with applicable European directives and regulations Indoor use only This device is designed to be used indoors onl...

Страница 7: ...r a longer period of time disconnect it from the power supply and store it in a dust free environment Always check the unit for possible damage before use If you suspect that something is wrong with t...

Страница 8: ...Speed Brightness FL Flash Strobe R Red intensity G Green intensity B Blue intensity W White intensity not available on this product A Amber intensity not available on this product JU Colour jump FA Co...

Страница 9: ...COL7 Colour preset RGBW CR00 CR99 Dimmer red CG00 CG99 Dimmer green CB00 CB99 Dimmer blue CF00 CF99 Flash speed strobe speed JUMP JU00 JU99 Colour jump speed JF00 JF99 Flash speed strobe speed FADE F...

Страница 10: ...o increase the sensitivity making sure that the fixture responds to the sound accurately The sensitivity can be adjusted from 0 to 100 100 being the most sensitive LED LED display on off If you use th...

Страница 11: ...f the first fixture The master slave function requires 3p XLR male XLR female cables not included Connect the DMX output of the master fixture to the DMX input of the second fixture and from this fixt...

Страница 12: ...s 1 Dimmer 0 100 000 255 2 Strobe slow fast 000 255 3 Red 0 100 000 255 4 Green 0 100 000 255 5 Blue 0 100 000 255 6 Colour preset 000 036 Colour 1 037 073 Colour 2 074 110 Colour 3 111 147 Colour 4 1...

Страница 13: ...es 54 powerful SMD RGB LEDs to create an immense number of colours The light source cannot be replaced by the user The device does not require cool down time after use before it is transported The Com...

Страница 14: ...n A maximum of 100 ComPar 2 fixtures can be daisy chained from the main ComPar 2 device Please make sure that no equipment with a power consumption higher than 2 000 W is connected to the output of th...

Страница 15: ...se or DMX activity signal LEDs active Check your DMX cables for possible connector breaks and replace them if necessary Wrong operating mode Switch the operating mode of the device to DMX mode The fix...

Страница 16: ...peration as Slave it is not possible to activate the automatic or music controlled modes Remote control does not work Aimed wrong The IR receiver of the device is placed on the front panel of the devi...

Страница 17: ...ur preset custom colour colour jump colour fade sound controlled operation adjustable sound sensitivity master slave operating mode Technical info connection voltage 100 240V AC 50 60 Hz fuse F3AL250V...

Отзывы: