Wire sizes
The use of any extension cable will cause
some loss of power. To keep this to a
minimum and to prevent overheating and
motor burn-out, use the table below to
determine the minimum wire size (lead
cross-section) of an extension cable. For
circuits that are more than 40m away from
the electrical service box, the wire size must
be increased proportionately in order to
deliver ample voltage to the saw motor.
Length of the
conductor
Wire Sizes
Required For 230V
Up to 15m
15-40m
1.5mm
2
2.5mm
2
5.Unpacking And Checking
Contents
the Metal Saw is shipped complete in one
carton. Separate all parts from packing.
Material and check each item with illustration
and “Table of Loose Part”. Make certain all
items are accounted for, before discarding
any packing material.
WARNINGA:
If any parts are
missing, do not try to assembly the
metal saw, plug in the power cable
or turn the switch on until the
missing parts are obtained and
installed correctly.
ITEM
TABLE OF LOOSE PARTS Q’TY
A
Basic Saw Assembly
1
B
Stop Rod Assembly
1
C
Saw Head Knob
1
D
90
º
Support Bar Assembly 1
E
Instruction Manual
1
Tool needed for assembly
Note:
The shown tools are not standard
deliver with this saw.
Medium Screwdriver Adjustable Wrench
Combination Square 13mm Hex. Soc. ”L” Wrench