4. Pressure Difference Threshold Interface
The machine has four pressure difference thresholds. Once the pressure difference between the
front and back of filter is higher than the threshold set by user, the machine will clean the dust
until the value is lower than the threshold.
The operation steps are as followings:
(1) Switch to the Pressure Difference Threshold Interface by pressing
, as shown in
Fig. 10-5.
500 Pa: Pressure difference threshold is 500 Pa.
1000 Pa: Pressure difference threshold is 1000 Pa
.
1500 Pa: Pressure difference threshold is 1500 Pa.
2000 Pa: Pressure difference threshold is 2000 Pa.
(2) Press
, move the cursor “>”to the desired parameter.
(3) Press
, the asterisk “*” will display in front of the desired parameter indicating that the
setting is working now.
Note:
The factory default threshold is 1000 Pa.
Fig. 10-5
5. Clean Allowed In Running Interface
The operation steps are as followings:
(1) Switch to the Clean Allowed In Running Interface by pressing
, as shown in
Fig. 10-6
.
Yes: Dust cleaning allowed in running.
No : Dust cleaning forbidden in running.
(2) Press
, move the cursor
“
>
”
to the desired mode.
(3) Press
, the asterisk
“
*
”
will display in front of the desired mode indicating that the setting
is working now.
Note:
The factory default setting is “Yes”