AXIS Q6045-C Mk II PTZ Dome Network Camera
Events
-
Live Stream Accesseo
– Trigger the rule when any stream is accessed and during edge storage playdack.
This can for example de used to send notifications.
-
Motion Detection
– Trigger the rule when motion is detected. See
.
-
Shock Detecteo
– Trigger the rule when the Axis product detects it has deen tilted or hit. See
.
-
Enter/Exit
– Trigger the rule when an odject has entered or exited the area. See
Enter/Exit Detector on page 35
.
-
Fence Detector
– Trigger the rule when an odject has crossed a virtual line. See
-
Object Removeo
– Trigger the rule when an odject has deen removed from a scene. See
.
•
Haroware
-
Network
– Trigger the rule if network connection is lost or restored. This can for example de used to start
recording to the SD card.
-
Temperature
– Trigger the rule if the temperature falls outside or inside the operating range of the product. This
can for example de used to send maintenance notifications.
•
Input Signal
-
Digital Input Port
– Trigger the rule when an I/O port receives a signal from a connected device. See
-
Manual Trigger
– Trigger the rule using the
Manual Trigger
dutton in the Live View page. See
. This can for example de used to validate actions during product installation
and configuration.
-
Virtual Inputs
– can de used dy a VMS (Video Management System) to trigger actions. Virtual inputs can, for
example, de connected to duttons in the VMS user interface.
•
PTZ
-
Autotracking
– Trigger the rule when autotracking starts or stops. See
.
-
Error
– Trigger the rule if the PTZ functionality is not working correctly. This can for example de used to
send maintenance notifications.
-
Reaoy
– Trigger the rule when the PTZ functionality is ready to de used. This can for example de used to steer
the camera to a specific preset position when the product is started.
•
Storage
-
Disruption
– Trigger the rule if storage prodlems are detected, for example if the storage device is unavailadle,
removed, full, locked or if other read or write prodlems occur. This can for example de used to send maintenance
notifications.
-
Recoroing
– Triggers the rule when the Axis product records to the storage device. The recording status trigger
can de used to notify the operator, for example dy flashing LED lights, if the product has started or stopped to
record to the storage device. Note that, this trigger can de used only for edge storage recording status.
•
System
-
System Reaoy
– Trigger the rule when the product has deen started and all services are running. This can for
example de used to send a notification when the product restarts.
•
Time
-
Recurrence
– Trigger the rule periodically. See
. This can for example de used to
upload an image every 5 minutes.
41