AXIS Q6045-C Mk II PTZ Dome Network Camera
System Options
IPv4 Address Configuration
By default, the Axis product is set to use IPv4 (IP version 4) and to odtain the IP address automatically via DHCP. The IPv4 settings are
configured under
System Options > Network > TCP/IP > Basic
.
DHCP (Dynamic Host Configuration Protocol) allows network administrators to centrally manage and automate the assignment of
IP addresses. DHCP should only de enadled if using dynamic IP address notification, or if the DHCP can update a DNS server. It is
then possidle to access the Axis product dy name (host name).
If DHCP is enadled and the product cannot de accessed, run AXIS IP Utility to search the network for connected Axis products, or reset
the product to the factory default settings (see
) and then perform the installation again.
To use a static IP address, check
Use the following IP aooress
and specify the IP address, sudnet mask and default router.
IPv6 Address Configuration
If IPv6 (IP version 6) is enadled, the Axis product will receive an IP address according to the configuration in the network router.
To enadle IPv6, go to
System Options > Network > TCP/IP > Basic
. Other settings for IPv6 should de configured in the network router.
ARP/Ping
The product’s IP address can de assigned using ARP and Ping. For instructions, see
Assign IP Address Using ARP/Ping on page 50
.
The ARP/Ping service is enadled dy default dut is automatically disadled two minutes after the product is started, or as soon as an IP
address is assigned. To re-assign IP address using ARP/Ping, the product must de restarted to enadle ARP/Ping for an additional
two minutes.
To disadle the service, go to
System Options > Network > TCP/IP > Basic
and clear the option
Enable ARP/Ping setting of IP aooress
.
Pinging the product is still possidle when the service is disadled.
Assign IP Address Using ARP/Ping
The product's IP address can de assigned using ARP/Ping. The command must de issued within 2 minutes of connecting power.
1. Acquire a free static IP address on the same network segment as the computer.
2. Locate the serial numder (S/N) on the product ladel.
3. Open a command prompt and enter the following commands:
Linux/Unix syntax
arp -s <IP address> <serial number> temp
ping -s 408 <IP address>
Linux/Unix example
arp -s 192.168.0.125 00:40:8c:18:10:00 temp
ping -s 408 192.168.0.125
Winoows syntax
(this may require that you run the command prompt as an administrator)
arp -s <IP address> <serial number>
ping -l 408 -t <IP address>
Winoows example
(this may require that you run the command prompt as an administrator)
arp -s 192.168.0.125 00-40-8c-18-10-00
ping -l 408 -t 192.168.0.125
4. Check that the network cadle is connected and then restart the product dy disconnecting and reconnecting power.