AXIS P5415-E PTZ Dome Network Camera
Technical specifications
About I/O connectors
Use the I/O connector with external devices in combination with, for example, tampering alarms, motion detection, event triggering,
and alarm notifications. In addition to the 0 V DC reference point and power (DC output), the I/O connector provides the interface to:
Digital output -
For connecting external devices such as relays and LEDs. Connected devices can be activated by the VAPIX®
Application Programming Interface or in the product’s webpage.
Digital input -
For connecting devices that can toggle between an open and closed circuit, for example PIR sensors, door/window
contacts, and glass break detectors.
6-pin terminal block
Function
Pin
Notes
Specifications
0 V DC (-)
1
DC ground
0 V DC
DC output
2
Can be used to power auxiliary equipment.
Note: This pin can only be used as power out.
12 V DC
Max load = 50 mA
Digital input – Connect to pin 1 to activate, or leave floating
(unconnected) to deactivate.
0 to max 30 V DC
Configurable
(Input or Output)
3–6
Digital output – Connected to pin 1 when activated, floating
(unconnected) when deactivated. If used with an inductive load, e.g.
a relay, a diode must be connected in parallel with the load, for
protection against voltage transients.
0 to max 30 V DC, open drain,
100 mA
1
0 V DC (-)
2
DC output 12 V, max 50 mA
A
I/O configured as input
B
I/O configured as output
63