AXIS P5414-E PTZ Dome Network Camera
System Options
Ports & Devices
I/O Ports
The Axis product provides four configurable input and output ports for connection of external devices. For information about
how to connect external devices, see
Connectors on page 67
.
To configure the I/O ports, go to
System Options
>
Ports & Devices
>
I/O Ports
. Each port can function as input or output:
•
Input as Open circuit – The input becomes active when the circuit is grounded by, for example, a REX device. It remains
inactive as long as its normal state equals its current status.
•
Input as Grounded circuit – The input becomes active when the circuit is opened by for example a monitor.
•
Output as Open circuit – The output port is in a non-conductive state when its current status is open circuit. The current
status of an output port can be changed by, for example, an action rule.
•
Output as Grounded circuit – The output port is in a conductive state when its current status is grounded circuit.
Port Status
The list on the
System Options > Ports & Devices > Port Status
page shows the status of the product’s input and output ports.
Maintenance
The Axis product provides several maintenance functions. These are available under
System Options > Maintenance
.
Click
Restart
to perform a correct restart if the Axis product is not behaving as expected. This will not affect any of the current
settings.
Note
A restart clears all entries in the Server Report.
Click
Restore
to reset most settings to the factory default values. The following settings are not affected:
•
the boot protocol (DHCP or static)
•
the static IP address
•
the default router
•
the subnet mask
•
the system time
•
the IEEE 802.1X settings
•
uploaded applications are kept but must be restarted
Click
Default
to reset all settings, including the IP address, to the factory default values. This button should be used with caution. The
Axis product can also be reset to factory default using the control button, see
Reset to Factory Default Settings on page 59
.
To test the product’s PTZ mechanics, click
Test
under
PTZ Status
.
For information about firmware upgrade, see
Upgrade the Firmware on page 61
.
57