30
OPERATION MANUAL BD/TL
__________________________________________________________________________________________________________________
SErIAL
Port-1 and Port-2 serial parameters :
-
transmission speed (
bAud)
: 1200, 2400
4800, 9600, 19200, 38400, 57600bps
,
-
quantity of bits in byte (
bitS)
:
7, 8
,
-
parity control (
ParItY)
:
none
– no control,
Odd
– non-parity
,
Even
- parity,
-
continous transmission (
Send
):
oFF –
transmission off,
StAb
– transmission after pressing
key and indication stabilization,
noStAb–
transmission after pressing
without stabilization,
Auto
– after putting on and taking off the product without pressing
,
Cont.
- about 10 results per second,
ReMOV –
transmission after taking off the product from the pan.
-
Transmision protocol
(Prot)
:
LonG
- printer
,
computer
Eltron
– label printer (activates
LAbEL
option),
Pen-01
– pendrive PEN-01 attachment.
- Port-1 and Port-2 printouts configurations (
):
HEAdEr
– header: name, model and scale nr,
USEr id –
user id (max 6 digits),
Prn no
– printout successive number (choosing this options resets the counter),
M id –
product number,
dAtE
–date (option),
tIME
– time (option),
Count
– counting result,
APW
– unitary mass,
netto
– net weight,
tArE
– actual tare value,
brutto
– gross weight,
totAL
– results sum,
nr LCD
– printout nr and measurement result displayed in one line.
Sound
turning on (On) or off (OFF) the sound.
FILtEr
turning on (-10, -20, -30, -40) or off (OFF) additional filters; filter
reduces the impact of mechanical vibrations on measurement result.
b_LIGH
backlighting settings:
- OFF
– backlight off,
- On –
backlight on,
- ECO
– turning off after 30s without any actions (no load change or using
keys),
- bAtt
– as above but only when supplied from accumulators.
rESOLU
turning on (LO) or off (HI) scale’s decreasing resolution option.
bAttEr
setting accumulator: