20
OPERATION MANUAL BD/TL
__________________________________________________________________________________________________________________
16.
Products data library
(
MEM key )
The scale is equipped with data library where user can save 1000 details.
Products base consists of:
-
M no
- record number (M0001÷1000), needed to recall to it,
-
M Id
– product code, inscribed by using keyboard or scanner,
-
APW
– product unit mass, used for pieces counting,
-
SAMPL
– inscribing quantity of products, above which counting results
correction algorithm turns on,
-
PtArE
– inscribing constant tare for product (not necessary),
-
thr Lo
– lower threshold value (not necessary),
-
thr Hi
– upper threshold value (not necessary),
-
thr Zr
- zero threshold value (not necessary).
During scale work, barcode reader readout of record number causes searching
through scale product library and in case of finding the right record recalling to
single piece mass and other product data.
Database can be built in Excel datasheet form, where each product has one row
and each column have product data. This way created database, saved in *.csv
extension with semicolons can be send to scale using
Scale Database
software
and scale’s serial interface.
Scale Database
is available on our webpage
www.axis.pl/en
.
Handy products banks
The scale is equipped with two handy detail banks: M1 and M2, that are related
to fast choice keys M01÷M15 and
M16÷M30
. Each key recalls proper number
record. Switching between handy detail banks is done by pressing MEM1/
MEM2
key (indicator on lower section display changes position from
M1
to
M2
or vice
versa signalizing which bank is used at the moment).
fast choice keys
memory switch
indicator on M1 position
Longer
pressing one of the fast choice keys causes displaying chosen parameter
edition menu.
Short
key
pressing recalls chosen record.
◄