This will cause printout of calculated statistics and
histogram :
LSL - allowable lower value,
USL - allowable upper value,
A, B, C, .. – measurement intervals,
n
A
... – amount of measurements in A interval;
measurement is in A interval if it is bigger or
equal to A interval threshold and smaller
than B interval threshold.
n
B
... - amount of measurements in B interval;
measurement is in B interval if it is bigger or
equal to B interval threshold and smaller
than C interval threshold.
Thresholds are printed under histogram.
-NG - amount of measurements under allowable
lower value
+NG - amount of measurements above allowable
upper value
To finish work with this function and zeroing result
register press
F
key, then during "
F..-StA
" and
"
F..-0
" is displayed, press
→
T
←
key. This will
cause printing message about register zeroing.
Cooperation between statistics function with computer and printer.
The scale can be equipped with two RS232C connections marked as RS232C-I (computer) and
RS232C-II (printer). After each printer data printout, identical set of data is send to computer.
After S A CR LF (53h 49h 0Dh 0Ah) initialization signal is sent by computer, the scale sends to
computer statistical data contained in histogram.
Data: ...
Hour. ...
SAMPLES
=
...
TOTAL MASS
=
...
AVER MASS
=
...
MIN MASS
=
...
MAX MASS =
...
MAX – MIN
=
...
S
=
...
SREL
=
...
*HISTOGRAM*
LSL
...
USL
...
DIV
...
-NG
...
LSL
A
n
A
B
n
B
C
n
C
D
n
D
E
n
E
F
n
F
G
n
G
H
n
H
I
n
I
J
n
J
USL
+NG
...
A
~
...
B
~
...
C
~
...
D
~
...
E
~
...
F
~
...
G
~
...
H
~
...
I
~
...
J
~
...
...
Measurement made by : ____________