14.15 Total weight function (totAL)
The function allows calculating total weight for series of measurements, which can
be grater than scale capacity. It allows calculating total weight as well as average
value.
Press
MENU
key.
When
totAL
is displayed press
→
T
←
key.
The
following
options
appear
successively:
-
tot-P
-
report printout without clearing
total register,
-
tot-0 -
clearing total register, report
printout and leaving the function,
-
tot-1 -
working with receipt printout
after each measurement,
-
tot-2
-
working
without
receipt
printout.
Press
→
T
←
key when
tot-1
is displayed.
Perform measurement series pressing
key for storing results into total register.
In order to print and display results enter
to function choosing
total
and
tot-P
option from menu
The results are display in the following
sequence:
- total weight (
≡
)
- number of registered measurements (
n
),
- average value (=
)
,
regarding
that
moving
to
display
successive result is performed after
pressing
key.
In order to go back to total weighing
without zeroing total register press
key third time.
0.00
0.00
totAL
totAL
tot- P
tot- 1
10.00
20.00
2
15.00
0.00
30.00
MENU
T
T
T
T
n
_
_
_
_
_