42
AXIS 207W/AXIS 207MW - The I/O Terminal Connector
The I/O Terminal Connector
Used in applications for e.g. motion detection, event triggering, time lapse recording, alarm
notifications, etc., the I/O terminal connector provides the interface to:
• 1 transistor output - For connecting external devices such as relays and LED:s.
Connected devices can be activated by Output buttons on the Live View page or
by an Event Type. The output will show as active (in Event Configuration > Port
Status) if the alarm device is activated.
• 1 digital input - An alarm input for connecting devices that can toggle between
an open and closed circuit, for example: PIRs, door/window contacts, glass break
detectors, etc. When a signal is received the state changes and the input becomes
active (shown under Event Configuration > Port Status).
• Auxiliary power and GND
The I/O terminal pins are numbered left to right, as shown below.
Connect input/output devices to the camera as follows:
1. Attach the cables for the device securely to the supplied green connector block.
2. Once the cables are connected, push the connector block into the terminal
connector (also green) on the camera.
Function Pin
No.
Notes
Specifications
Transistor
Output
Pin 4
Uses an open-collector NPN transistor with the
emitter connected to the GND pin. If used with
an external relay, a diode must be connected in
parallel with the load, for protection against
voltage transients.
Max load = 100mA
Max voltage = 24V DC
(to the transistor)
Digital
Input
Pin 3
Connect to GND to activate, or leave floating
(or unconnected) to deactivate.
Must not be exposed to
voltages greater than
10V DC
GND
Pin 1
Ground
Auxiliary
DC Power
Input
Pin 2
Electrically connected in parallel with the con-
nector for the power supply, this pin provides
an auxiliary connector for mains power to the
unit.
This pin can also be used to power auxiliary
equipment, with a maximum current of 50mA.
Voltage:
AXIS 207W: 4.9-5.1V
DC, max 3.5 W
AXIS 207MW: 4.9-5.1V
DC, max 4.0 W
1