INSTRUCTION MANUAL
19
_____________________________________________________________________________________________________________________
8.3 Preparing foundation scales
8.3.1 Preparing foundation
CAUTION!
Decision of substrate reinforcing and density is taken by building works designer.
All dimensions are in millimetres.
During foundation preparation follow the principles below:
1.
Foundation and feet under balance legs should be made from concrete. Foundation bottom thickness
should not be smaller than 100 mm.
2.
Foundation bottom inclination angle (shown in fig. 1 on page 8) should be at least 3%.
3.
Keep the same level for all feet.
4.
Level the foundation frame, keeping perpendicularity of sides and equality of diagonals.
5.
Diameter of PVC pipe for cables to connection box should be at least 50 mm.
6.
Keep the area free from reinforcing bars as shown in fig. 2 on page 8.
7.
Foundation external and internal dimensions, proper for various platform dimensions are shown in table
below.
Balance type Platform dimensions
[mm]
Foundation internal
dimensions
(WxLxH) [mm]
Foundation enternal
dimensions
(WxL) [mm]
4B300FN
800x800
820x820x128
1220x1220
4B300FN
1000x1000
1020x1020x128
1420x1420
4B300FN
1250x1250
1270x1270x128
1670x1670
4B600FN
800x800
820x820x128
1220x1220
4B600FN
1000x1000
1020x1020x128
1420x1420
4B600FN
1250x1250
1270x1270x128
1670x1670
4B1500FN
1250x1250
1270x1270x128
1670x1670
4B1500FN
1500x1500
1520x1520x128
1920x1920
4B2000FN
1250x1250
1270x1270x128
1670x1670
4B2000FN
1500x1500
1520x1520x128
1920x1920
4B3000FN
1500x1500
1520x1520x128
1920x1920
4B3000FN
1500x2000
1520x2020x128
1920x2420
Keep all dimensions, shown in drawings and table.
Careless and inaccurate foundation preparation may make balance
installation impossible or cause its improper operation!