AMI BIOS Fatal Error Codes
88
!
$%
5!
7
&6%6%$
+
"
"
Beeps Error
Message
Description
1
Refresh Failure
The memory refresh circuitry is
faulty.
2
Parity Error
Parity error in the base memory (the
first 64 KB block) of memory.
3
Base 64 KB Memory Failure
Memory failure in first 64 KB.
4
Timer Not Operational
A memory failure in the first 64 KB
of memory, or Timer 1 is not
functioning.
5
Processor Error
The CPU generated an error.
6
8042 - Gate A20 Failure
Cannot switch to protected mode.
7
Processor Exception Interrupt
Error
The CPU on the CPU Card
generated an exception interrupt.
8
Display Memory Read/Write
Error
The system video adapter is either
missing or its memory is faulty. This
is not a fatal error.
9
ROM Checksum Error
The ROM checksum value does not
match the value encoded in
AMIBIOS.
10
CMOS Shutdown Register
Read/Write Error
The shutdown register for CMOS
RAM has failed.
11
Cache Memory Bad — Do Not
Enable Cache
The cache memory test failed.
Cache memory is disabled. Do not
press <Ctrl> <Alt> <Shift> <+> to
enable cache memory.
Содержание SBC8241
Страница 1: ......
Страница 4: ......
Страница 6: ...Table of Contents...
Страница 7: ...Table of Contents...
Страница 8: ......
Страница 12: ...SBC8241486 All in One Half size CPU Card User s Manual...
Страница 13: ...SBC8241 486 All in One Half size CPU Card User s Manual Jumpers and Connectors...
Страница 16: ...SBC8241 486 All in One Half size CPU Card User s Manual...
Страница 31: ...SBC8241 486 All in One Half size User s Manual AMI BIOS Setup 8 6 4 B 6 5 2 C5 D 6 3 C5 D 6 3 4 6 6 6 6 3 6...
Страница 34: ...SBC8241 486 All in One Half size User s Manual 2...