ETM710 VIA V4 ETX v3.0 SoM User’s Manual
Watchdog Timer
56
↓
WDT counting re-set timer:
O 2E F4
O 2F M; M=00, 01, 02…FF (See below table)
IF to disable WDT:
O 2E 30
O 2F 00; Can be disable at any time
z
Timeout Value Range
1 to 255
Minute / Second
z
Program Sample
Watchdog Timer can be set to system reset after 5-second
timeout.
2E, 87
2E, 87
2E, 07
2F, 08
Logical Device 8
2E, 30
Activate
2F, 01
2E, 29
Select Port
2F, 20
WDTO#
2E, F3
2F, N
Set Minute or Second
N=00 (Sec),04(Min)
2E, F4
2F, M
Set Value
M = 00 ~ FF