Installation
Instructions
(Continued)
NOTE:
For certain applications, conduit
may be required (see Figure 6). Check
local electrical codes. If you run the
wiring in conduit and wish to be able
to turn the heater be sure to purchase
enough flexible conduit to allow the
heater to be turned.
3. Connect the wire to the power block
located in the base of the heater
(see Figure 7).
NOTE:
Unit is 240/208 volts. When
wiring a two conductor cable with
ground, the white wire must be marked
black by adding a piece of black
electrical tape to the wire near
the point of connection.
NOTE:
To decrease the heat output
of the heating unit, see Table 1 and
Figure 9.
4. Turn on the power at the main
service panel.
Dayton
®
Electric Utility Heaters
3UG73E and 3UG74E
Dayton Operating Instructions and Parts Manual
Figure 8 – Adjustable Louvers
L1
L2
Figure 7
BLK
1
2
3
4
5
6
ELEMENT
HI
LIMIT
FAN
CONT.
7
8
9
10
11
12
C D
A B
WATTAGE CHANGE
TERMINAL BOARD
GROUND
THERMOSTAT
L1
L2
POWER
TERMINAL
BLOCK
FIELD
WIRING
FAN
ALARM LIGHT
MOTOR
RD
YL
BLU
Figure 9 – Wiring Diagram
WIRING
208/240V - 3UG73E
208V - 3UG74E
NOTE:
1. Do not move blue wire at L1.
(Table 1 refers to blue wire
at terminal T.)
2. It is recommended that
#10 AWG wire be used in
all installations to provide for
possible future reconnection
at the higher wattage. Refer
to NEC (National Electrical
Code) for maximum run
length to minimize voltage
drop to 3% max. Circuit runs
exceeding 100 ft. may require
larger conductor size).
3. Wires #2, #3, & #4 should be
routed through indicated
element jumper wire
eliminating use of wire tie.
Green (or
Bare Copper)
Bottom
View
Power
Terminal Block
Black
White
3UG73E
17065
240
5000
30
20.9
None
14215
240
4165
25
17.4
Blue
11365
240
3332
20
13.9
Blue & Yellow
8533
240
2500
15
10.4
Blue, Yellow & Red
12799
208
3750
25
18.0
None
10659
208
3123
20
15.0
Blue
8533
208
2500
15
12.0
Blue & Yellow
6393
208
1874
15
9.0
Blue, Yellow & Red
3UG74E
17065
208
5000
30
24.0
None
14215
208
4165
25
20.0
Blue
11365
208
3332
20
16.0
Blue & Yellow
8533
208
2500
15
12.0
Blue, Yellow & Red
Table 1 – Heat Output Adjustments
Max
Heater
Move Jumpers
Model
BTU/Hr.
Volts
Watts
Fuse Size
Amps
from C-D to A-B
Содержание PRO-GUARD
Страница 1: ...PRO GUARD Emergency Shower Operation Maintenance Manual 00102 R0 OM 12 08 ...
Страница 2: ...Emergency Shower Manual Operation Maintenance 00102 R1 OM 16 01 Revised January 14 2016 Page 2 of 22 ...
Страница 18: ...Emergency Shower Manual Operation Maintenance 00102 R1 OM 16 01 Revised January 14 2016 Page 18 of 22 ...