TPSK 12 & 24 V User’s Manual
Page 58 / 66
Reference: FDE 31 08 972 Issue Z
SET
AUTOTEST
AFTER
CLOSE
MODE
ASCII
US
ETX
n
Hexadecimal
1F
03
AA
n
Decimal
31
3
178
n
Value of
n
0 = disable
1 = enable
Range of
n
0-1
Default
1 (enable)
S
ET
V
OLTAGE
M
ECHANISM
This command will store the Voltage Mechanism parameter setting in non-volatile memory.
ASCII
US
ETX
í
n
Hexadecimal
1F
03
A1
n
Decimal
31
3
161
n
Operand:
n
= Mode selection
Value
Decimal
0
12 Volts
10.8V
≤
voltage range
≤
13.2V (On
Average)
1
24 Volts
20.0V
≤
voltage range
≤
26.4V (On
Average)
Default
1
Limit :
Dec: 0
≤
n
≤
1
Hex: 00
≤
n
≤
01
Note :
Voltage range: components tolerance not taken into consideration.
This command must be followed by a reset.
P
APER
L
OW
S
ENSOR
O
PTION
This command will store the paper low sensor option in non-volatile memory (NVRAM).
ASCII
US
ETX
ETX
n
Hexadecimal
1F
03
03
n
Decimal
31
3
3
n
Operand:
n
= mode Selection
Value
Decimal
0
Disabled
1
Enabled (Sensor)
2
Enabled (switch)
Default:
0
Limit:
Dec: 0
≤
n
≤
2
Hex: 00
≤
n
≤
02
Note: