Reference: FDE 31 08 972 Issue Z
Print Bar Code (continued)
Values
First Variation: Data string terminated with NULL Character
M
Bar Code
D
n, Length
0
UPC-A
48- 57 (ASCII numerals)
Fixed Length: 11, 12
1
UPC-E
48- 57
Fixed Length: 11, 12
2
JAN13 (EAN)
48- 57
Fixed Length: 12, 13
3
JAN8 (EAN)
48- 57
Fixed Length: 7,8
4
Code 39
48- 57,
65- 90 (ASCII alphabet),
32, 36, 37, 43, 45, 46, 47 (ASCII special
characters)
d1 = dk = 42 (start/stop code is supplied by
printer if necessary)
Variable Length
5
Interleaved 2 of 5
48- 57
Variable Length
(Even Number)
Second Variation Length of Byte Specified at Beginning of String
The value of m selects the bar code system as described in the table.
The variable d indicates the character code to be encoded into the specified bar code system. See the table. If
character code d cannot be encoded, the printer prints the bar code data processed so far, and the following
data is treated as normal data.
m
Bar Code
D
n
, Length
65 UPC-A
48- 57 (ASCII numerals)
Fixed Length: 11, 12
66 UPC-E
48- 57
Fixed Length: 11, 12
67 JAN13 (EAN)
48- 57
Fixed Length: 12, 13
68 JAN8 (EAN)
48- 57
Fixed Length: 7, 8
69 CODE39
48- 57,
65- 90 (ASCII alphabet),
32, 36, 37, 43, 45, 46, 47 (ASCII special
characters)
d1 = dk = 42 (start/stop code is supplied by
printer if necessary)
Variable
70 Interleaved 2 of 5
(ITF)
48- 57
Variable (Even
Number)
73 Code 128
0-105
d1 = 103-105 (must be a Start code)
d2 = 0-102 (data bytes)
(Stop code is provided by the printer)
Variable