Reference: FDE 31 08 972 Issue Z
5.11 Bar code commands
These commands format and print bar codes.
S
ELECT
P
RINTING
P
OSITION OF
HRI
C
HARACTERS
Prints HRI (Human Readable Interface) characters above or below the bar code.
ASCII
GS H n
Hexadecimal
1D 48
n
Decimal
29 72 n
Value of
n
Printing position
0 = Not printed
1 = Above the bar code
2 = Below the bar code
3 = Both above and below the bar code
Default
0 (Not printed)
S
ELECT
P
ITCH OF
HRI
C
HARACTERS
Select font used to print HRI characters.
ASCII
GS f n
Hexadecimal
1D 66
n
Decimal
29 102 n
Value of
n
0 = Standard Pitch at 12.7 CPI
1 = Compressed Pitch at 16.9 CPI
Default
1 (Standard Pitch at 16.9 CPI)
S
ELECT
B
AR
C
ODE
H
EIGHT
Sets the bar code height to n dots or n/203 inch (n/8 mm).
ASCII
GS h n
Hexadecimal
1D 68
n
Decimal
29 104 n
Value of
n
Number of dots
Range of
n
1-255
Default
216