  Th is Dat asheet   is pr esent ed by  t he m anuf act ur er .  

 
Please v isit  our   websit e f or  pr icing and av ailabilit y  at  

w w w.hest or e.hu

.

 

Содержание AX-C800

Страница 1: ...EN This Datasheet is presented by the manufacturer Please visit our website for pricing and availability at www hest ore hu ...

Страница 2: ...Volt Ma Calibrator AX C800 OPERATION MANUAL ...

Страница 3: ...Calibrator is a source and measurement tool This Calibrator is use to measure or output 0 to 24 mA DC current loop and 0 to 15 DC voltage But the calibrator cannot be used to measurement and source simultaneously Volt mA Calibrator include this accessories Holster a pair of Test Leads AAA 6 battery and this manual If the calibrator is broken or short of some accessories please contact the supplier...

Страница 4: ...A 0 001 mA 0 015 3 Overload protection 250V Fast acting fuse Percent display 0 4 mA 100 20 mA Source mode Compliance 1000Ω at 20mA for battery voltage 6 8V 700 Ω at 20mA for battery voltage 5 8 to 6 8V Simulate mode External loop voltage requirement 24V nominal 30V maximum 12V minimum Loop power 24 V 10 General specifications Maximum voltage applied between any jack and earth ground or between any...

Страница 5: ...th ground Conform to European Union directives Refer to his instruction sheet for information abort his feature Explanation on Front Panel The front panel is show as in right figure 1 Loop power 24V to ground 2 mA measurement input jack 3 Input or output negative ground jack 4 V mV input or output jack 5 Power switch 6 V mV conversion key 7 mA mA conversion key 8 Input Output conversion key ...

Страница 6: ...tate of measurement 3 Press the V MV conversion key 6 make it indicate mVDC 17 4 Put the red test lead in V jack 4 black one to the COM jack 3 5 Connect the red test lead with the positive of voltage which is waiting for measurement black one to the negative ground 6 The value of result show 16 The number In the refering to the Explanation on Front Panel Page 5 DC V output 1 Press the Power switch...

Страница 7: ...mV conversion key 6 DC mA measurement Outside supply power measurement 1 Press the Power switch 5 turn on the Calibrator 2 Press the input output conversion key 8 when the state of no input indicator 14 Make it under the state of measurement 3 Press the mA mA conversion key 7 make it indicate mA or mA 18 at the state of measure you Reed 4 Put the red test lead In mA Jack 2 black one to the COM jac...

Страница 8: ... the state of no input indicator 14 Make it under the state of measurement 3 Press the mA mA 18 at the state of measure you need 4 Put the red test lead in LOOP jack 1 black one to the mA jack 2 5 Connect the red test lead with the in of current which is waiting for measurement black one to the out of current 6 The value of result show 16 ...

Страница 9: ...the red lead with the positive of current which is waiting for output black one to the negative 7 If you want to change the output value or state then press the value adjust key 9 10 11 12 or the mA mA conversion key 7 Simulating a Transmitter 1 Press the power switch 5 turn on the Calibrator 2 Press the input output conversion key 8 when the state of no output indicator 15 Make it under the state...

Страница 10: ...re that it performs according to its specifications Replacing the Battery Please change the battery when the LCD indicates Turn if the power of the Calibrator when you change the battery and screw off the breechblock on the battery cabinet cover then take off it and instead the fresh battery Replacing a Fuse Warning To avoid personal injury or damage to the calibrator use only a 0 125A 250V Fast f...