Operation instructions | MIP 8-00 | MIP 16-00 | MIP 8-06 | MIP 16-06
Page 24 of 48
BA_MIP-8-16-0x.pdf | Technical improvements, changes in design, printing- and other errors reserved. | 2022-01-10
4.2.6.
MPTS – Advanced options
In Phase 2 click on ADVANCED OPTIONS.
A dialog with options will open.
Specify a special PID for the Event Information Table (EIT).
In some countries the EIT is not transmitted with PID 18 (e.g. Israel PID 90). In this case, the headend can change this PID to
PID 18.
Open the
Advanced options
option field and below it the
EIT option
field.
For tuners 1 to 8 or 16, enter the PIDs used to transmit the EIT.
The entered PID of the EIT is then converted to PID 18.
Specify a special PID of the Service Description Table (SDT).
The Service Description Table (SDT) contains information about the transmitted programmes (services). It is usually transmitted
with the PID 17. However, if the SDT is transmitted with a different PID, the headend can change this other PID to PID 17.
Open the Advanced Options option panel, and below that, the SDT option panel.
The currently used SDT PIDs of the individual tuners are displayed (PID 17 ex works).
For tuners 1 to 8 or 16, enter the PIDs used to transmit the SDT. Permissible values are 32 to 8190.
The entered PID of the SDT is then converted to PID 17.