Chapter 2 |
14
Surface Operation
Remote
Many of the important operations that are achieved from the surface can also be controlled remotely from the web browser. A
simple static display with controls is offered from the Remote link that allows for simple control.
From the page, the Show Profile, Record mode, Source Profiles, Fader Gain, Channel States can be changed, and you can
control the monitor section.
Overbridge
The overbridge is composed of three displays. Two displays are dedicated to displaying audio meters while the third display is a
clock and count-up timer.
Audio Meters (A)(B)
You can access the web UI configuration through the Customize link. There you’ll find the Meters section, giving the mode and
count options as explained below.
You can configure the two displays for audio meters to be in one of three count modes, “2 meters,” “3 meters,” or “4 meters.”
In 2 Meters Display
, the audio meters will span the full width of the displays. The METER button on the monitor section would
be used to toggle the (B) display to different sources. The (A) display would be fixed to Program 1.
In 3 Meters Display
, the (B) display would be split in two with two meters shown. Again the METER button would toggle the
last meter while the second meter would be fixed to Program 2.
In 4 Meters Display,
both displays would be split showing Program 1, 2, 3 and the fourth meter being toggled between Program
4 and the Control Room monitor selection.
The meters have three ballistic options (modes), Full Scale VU, EBU Digital Peak, and PPM. The Full Scale VU is an RMS
presentation with an added Peak indicator. The other two are peak presentations based on those standards. The mode is changed
from the web UI and takes effect immediately.