Axi STS 7030 Скачать руководство пользователя страница 25

OPERATION 

! WARNING ! Do not use with gasoline. This System is not meant for use with gasoline 
nor with other flammable liquids having a flash point less than 100°F. Use with gasoline 
or use with any flammable liquids at a temperature exceeding their flash point, 

presents an immediate explosion and fire hazard. 

 

! WARNING ! Never use the STS 7030 at a temperature exceeding the flash point of its 

contents. 

EMERGENCY STOP 

Note:  In case of an emergency the pump can be turned off and disabled by depressing the red 

“EMERGENCY STOP” button on the control panel. 

 
To release the “EMERGENCY STOP” button located on the control panel turn the red knob in the direction 
indicated by the arrows on the mushroom button and push the “ALARM RESET” button to acknowledge. 
 

PUMP OPERATION 

Apply  control  power  to  unit.  Place  breakers  in  the  AXI  International  Smart  Filtration  Controller  in  the  “ON” 
position. 

Automatic: 

Place the key switch in the “AUTO” position. When the timer contacts close, the pump will start and run 
until the timer setting has expired. 

Manual (Override): 

Place the key switch in the “RUN” position. The pump motor will run until the switch is returned to the 
“OFF” or “AUTO” mode positions or till an alarm or overload has been tripped. 
 

SETTING THE CURRENT TIME AND DATE 

Note: PLC uses military time – all times must be programmed in that format. 

 

1.

 

From the STS 7004 Home Screen, touch and hold the screen background for 5 seconds to enter 
the Info Mode Menu. 

2.

 

Touch the “Enter Info Mode” button. 

3.

 

Enter 4 digit security code. 

4.

 

Touch the “Time & Date” button. 

5.

 

Touch the Date value to set the Date. Use dd/mm/yy format. 

6.

 

Touch the Time value to set the current time. 

7.

 

Press ESC to navigate back to the STS 7004 Home Screen. 

 

Содержание STS 7030

Страница 1: ...uct Submittal Package STS 7030 Automated Fuel Filtration System Modbus TCP IP LAN and Internet Connectivity E mail SMS Maintenance Alerts Maintenance Alert Log File Multiple tank Functionality Runtime...

Страница 2: ...Optimal Fuel Quality Reliable Power Product Submittal Package Section 1 CSI Specifications...

Страница 3: ......

Страница 4: ...closure with appropriate ventilation Hinged front doors shall be equipped with quarter turn key lockable handle Fluid containment area with leak detection shall be an integral component of the enclosu...

Страница 5: ...on a dedicated webpage that monitors the system as well as delivered through E mail and SMS messages to designated individuals System shall provide following control and display function a Full Modbu...

Страница 6: ...in accordance with the input from pressure and vacuum gauges as well as water sensor D Operation System shall provide dry contacts for summary alarm and leak detection alarm to interface with buildin...

Страница 7: ...Optimal Fuel Quality Reliable Power Product Submittal Package Section 2 Installation Operation Maintenance Manual...

Страница 8: ......

Страница 9: ...perating and Maintenance Manual STS 7030 Automated Fuel Filtration System Modbus TCP IP LAN and Internet Connectivity E mail SMS Maintenance Alerts Maintenance Alert Log File Multiple tank Functionali...

Страница 10: ...2...

Страница 11: ...ALARM FEATURES 14 INITIAL START UP COMMISSIONING CHECKLIST 15 Flow switch setting adjustment No Flow Alarm 15 Gauge venting accuracy 15 Initial test procedure 15 OPERATION 17 Emergency Stop 17 Pump O...

Страница 12: ...4...

Страница 13: ...2 x 17 142 x 183 x 43 cm Weight 688 lbs Not for use with fluids that have a flash point below 100 F All STS Systems feature Multi stage water removal and particulate filtration NEMA 12 13 4 Powder Coa...

Страница 14: ...a fully enclosed lockable weatherproof NEMA rated cabinet The principal components are a continuous duty motor with coupled gear pump a strainer primary coalescing filter with vacuum sensor and gauge...

Страница 15: ...ear Pump 18 Outlet Ball Valve 9 Pressure Relief Valve 19 Fuel Outlet 10 Pressure Gauge 20 Storage Shelf wer are cover e and es and F JG GVFM load MFSBUF turning back to JOH every OUBJOT Inside the STS...

Страница 16: ...tandards for safe operation NOT for use with fluids that have a flash point below 100 F 38 C e g gasoline alcohol SYSTEM COMPONENTS CONTROL AND SAFETY DEVICES AXI International Touch Screen Controller...

Страница 17: ...phosphatized surfaces Spill tray with leak detection Louvered side panels Brackets for wall mounting Literature pocket STAINLESS STEEL PLUMBING PRIMARY INSPECTION Upon arrival the STS 7030 Automatic...

Страница 18: ...shown on the electrical drawings WARNING The whole system Enclosure doors plumbing motor electric sub panel must be properly grounded for operator safety Depending on length of run use copper wiring...

Страница 19: ...the lowest possible fuel level in the tank A priming tee should be installed on the highest point of the suction line to be able to easily prime the lines and system The return line s should be plumb...

Страница 20: ...stem to prevent any possible interference with safe engine operation It is highly recommended to plumb the discharge line independent and separate of the engine s fuel return line back to the tank If...

Страница 21: ...installed at the fuel tank to hold the fuel column 5 Make sure to completely fill suction line to its highest point with fuel no trapped air in particular when the suction line exits the tank top and...

Страница 22: ...ATURES The STS 7030 is equipped with an AXI INTERNATIONAL Touch Screen Controller System and alarm status are displayed on the industrial control panel on the door via indicator lights and on the text...

Страница 23: ...ro due to internal case pressure buildup caused by temperature variations Accuracy may be significantly reduced To restore gauge to operating condition move yellow lever of fill plug to the open posit...

Страница 24: ......

Страница 25: ...PUMP OPERATION Apply control power to unit Place breakers in the AXI International Smart Filtration Controller in the ON position Automatic Place the key switch in the AUTO position When the timer con...

Страница 26: ...EAK DETECTION indicator The pump motor will shut off and remain locked out of operation until the leak has been corrected and the ALARM RESET button has been pushed Before removing the spilled fuel fr...

Страница 27: ...of 8 hours day and five days a week o Prior to performing the maintenance procedure ensure that 1 The electrical sub panel mounted main disconnect switch is operating properly 2 the user supplied remo...

Страница 28: ...dicator should start blinking for 10 seconds and then illuminate constantly as the pump is turned off Slide flow switch back into original position and reset alarm by pushing the RESET ALARM button No...

Страница 29: ...ump will automatically shut off and activate the HIGH PRESSURE ALARM indicator light The signal indicates that it is time to change the filter element There are several types of filters available the...

Страница 30: ...ER SEPARATOR If the water level in the secondary filter water coalescer reaches a certain level in the bowl the water sensor will trigger the alarm HIGH WATER ALARM and shut off the pump The signal in...

Страница 31: ...priately dimensioned Alarm HIGH VACUUM ALARM comes on with clean strainer element installed 1 Heavily contaminated fuel excessive water in tank 2 Restriction in plumbing on inlet side too high 3 Exces...

Страница 32: ...al Motor does not turn or turns intermittently 1 Control power not available 2 Motor thermal overload condition 3 Pump failed and seized 4 Motor failure 5 Emergency Button depressed Pump leaks fuel 1...

Страница 33: ...epair return removal or replacement of products AXI INTERNATIONAL ASSUMES NO LIABILITY FOR ANY GENERAL SPECIAL INCIDENTAL CONSEQUENTIAL CONTINGENT OR OTHER DAMAGES UNDER ANY WARRANTY EXPRESS OR IMPLIE...

Страница 34: ...element 10 Micron FBO 60341 Micro filter element 25 Micron Secondary Filter FBO 60336 Coalescing filter element 1 Micron FBO 60337 Coalescing filter element 5 Micron FBO 60356 Coalescing filter elemen...

Страница 35: ...Inside Diameter JB Junction Box HG Inches of Mercury L Lamp L E D Light Emitting Diode LFF Loss of Flow Relay LFL Low Fuel Level Relay LPR Low Pressure Relay MDB Main Distribution Block MDS Main Disco...

Страница 36: ...28 APPENDIX B DRAWINGS...

Страница 37: ...Optimal Fuel Quality Reliable Power Product Submittal Package Section 3 Electrical Drawing...

Страница 38: ......

Страница 39: ......

Страница 40: ...Optimal Fuel Quality Reliable Power Product Submittal Package Section 4 Installation Notes Recommendations for Site and or Tank Plumbing...

Страница 41: ...There are no additional installation notes or recommendations Please see the product manual included in this submittal for installation information...

Страница 42: ...ingle source for all fuel conditioning related equipment and support available world wide Peak Engine Performance Reliable Power Supply Lower Maintenance Costs Lower Exhaust Emissions Read about the s...

Отзывы: