![Axeon Water Technologies L1-Series Скачать руководство пользователя страница 17](http://html1.mh-extra.com/html/axeon-water-technologies/l1-series/l1-series_user-manual_3036162017.webp)
L1-Series User’s Manual
MKTF-258
17
9/14
PREPARING UNIT FOR STORAGE OR SHIPMENT
Prior to shipping or storing your system, the system should be cleaned
with an appropriate cleaner, flushed with water and protected from biological
attack with an appropriate solution for membrane elements. The membrane
housing(s) and plumbing lines of the system must be completely drained. Any
water remaining in the plumbing of a system may freeze, causing serious
damage.
Preparing system for storage:
1. Totally fill membrane elements in the membrane housing with 2 % M-100
solution, venting the air outside of the pressure vessels. Use the overflow
technique: circulate the M-100 solution in such a way that the remaining air in
the system is minimized after the recirculation is completed.
2. Check the pH once a week. When the pH becomes 3 or lower, change the
preservation solution.
3. Repeat this process at least once a month.
During the shutdown period, the plant must be kept frost-free, or the temperature
must not exceed 113°F (45°C).
Preparing unit for shipment:
4. Disconnect the inlet, concentrate, pre-filter, and permeate plumbing.
5. Drain all water from the pre-filter cartridge housings by unscrewing the
housings, removing the pre-filter cartridges, and drain the water from the
housings.
6. Disconnect the tubing from the connectors on the permeate and concentrate
inlets and outlets.
Allow the system to drain for a minimum of eight hours or until the opened ports quit
dripping.
After draining is complete, reconnect all of the plumbing.
Содержание L1-Series
Страница 1: ...Membrane System User s Manual L1 Series...
Страница 2: ...L1 Series User s Manual MKTF 258 2 9 14 This Page Left Blank...
Страница 11: ...L1 Series User s Manual MKTF 258 11 9 14 SYSTEM IDENTIFICATION...
Страница 15: ...L1 Series User s Manual MKTF 258 15 9 14 SPECIFICATIONS...
Страница 23: ...L1 Series User s Manual MKTF 258 23 9 14 SYSTEM DRAWING...
Страница 24: ...L1 Series User s Manual MKTF 258 24 9 14 L1 300 FLOW DIAGRAM...
Страница 25: ...L1 Series User s Manual MKTF 258 L1 SERIES ELECTRICAL 25 ELECTRICAL SCHEMATIC 110V 60HZ 9 14 110V 60HZ...
Страница 26: ...L1 Series User s Manual MKTF 258 L1 SERIES ELECTRICAL 26 ELECTRICAL SCHEMATIC 220V 50HZ 9 14 0HZ...