11/13
Inline Sight Glass
Operating Instructions
15
3.3 General Data
HAZARD
AWH inline sight glasses must only be operated with the safety screen in place.
Otherwise there is an injury
“HAZARD”
from broken glass if the cylinder is faulty.
Max. permissible operating temperature:
80°C (depends on sealing material and medium)
Max. permissible operating pressures:
DN
10
1/2"
15
20
25
1"
32
1 1/4"
40
1 1/2"
50
2"
2 1/2"
65
3"
80
100
4"
125
150
PN (bar)
10
9
8
7
7
7