Auto power-off of thermal imager
The battery power is exhausted.
→
Replace the battery.
The power-off duration is set in the display
setting.
→
Select "None" option here.
Battery power drains too fast
The ambient temperature is too low.
The rechargeable battery isn’t fully charged.
→
Recharge the rechargeable battery.
The rechargeable battery power is exhausted and
the battery can no longer be charged.
→
Replace it with a new rechargeable battery.
No thermal image
The lens cap is not removed.
→
Remove the lens cap.
In frozen image status
→
Press quit button to return to the real-time
temperature measurement status.
The thermal image is turned into
black and white status
Black and white color code is selected.
→
Select the normal color code.
42
7
Common Failure Countermeasures
Symptoms
Causes & Solutions
Failure to startup the Thermal
Imager
The battery isn’t installed or incorrectly installed.
→
Install or reinstall the battery.
The battery power is exhausted.
→
Replace the battery.
Thermal imager power-off protection
→
Wait 5 seconds and restart the device.
In case of any problem during utilization of the thermal imager, please adopt the
table below for maintenance. If the problem cannot be resolved, please
disconnect the power supply and contact our maintenance department.