background image

(Figure1)

h. EMS: Emissivity setup--press 5 keys for emissivity 
     settings, press 4 key to save setup and back to  
     normal status.         
(7) LCD
(8) Battery door clip
(9) Battery door: When replace battery door, please 
       press battery door clip and pull  the battery door.
(10) Clesius / Fahrenheit switch: Please open battery  
        and push the slide switch for con-vertsion
        

Maintenance

       1) Lens cleaning: Blow off lose particles using 
           clean compressed air. Gently brush remaining 
           debris away with a moist cotton cloth.
       2) Case cleaning: Clean the case with  a damp 
            sponge/cloth and mild soap.
Note:
      1) Do not use solvent to clean lens.
      2) Do not submerge the unit in water.

(3)

(6) key functions: press 3 key, LCD subdis-

         play blinks MAX-MIN-DIF-AVG-HAL-LAL-
         STO segment(only main display means normal
         measuring mode) press 4 key to enter.
a. MAX: measuring maximum temperature
b. MIN: measuring minimum temperature
c. DIF: Basic on the reading before press 4 key,
    compute the difference of current reading.
d. AVG: measuring average temperature
e. HAL: high temperature alarm--when selected
    HAL, press 5 keys to set high temperature alarm
    trigger and confirmed by pressing 4 key. When
    reading over trigger, LCD display HI icon with
    BiBi audio sounds. 
f.  LAL: low temperature alarm--when selected
     LAL, press 5 keys to set low temperature alarm
     trigger and confirmed by pressing 4 key. When 
     reading over trigger, LCD display LOW icon with
     BiBi audio sounds
g. STO: data storage--when selected STO, lock & 
    DATA & 1---indicator will shown when press 4 key.
     After temperature read out press 6 key to store, 
    then 2---memory unit will be shown. There 12 
    groups memory unit available. To recall the stored 
    data in normal measuring mode by press-ing 6 key, 
    remove all data by pressing 6 keys for 2 secretary.
    

A

B

C

D

E

F

G

C

F

HOLD

SCAN

LOW

HIGH

DATA

H

J

I

K

(Figure4)

2

SET

STO/CAL

LASER

BACKLIT

MODE

1

7

5

6

5

8

4

3

(Figure3)

9

Quick start instruction 

Non-contact infrared thermometer

            Instruction manual

Cautions
   Infrared thermometer should be protected for the
   following: 
--EMF (electro-magnetic fields) from arc weld-ers,
   induction heaters.
--Thermal shock (cause by large or abrupt ambi-ent
   temperature changes allow 30 minutes for unit to
   stabilize before use). 
--Do not leave the unit on or near objects of high 
   temperature.
Warning
   Do not point laser directly at eye or indire-ctly off 
   reflective surfaces.

    

3. Field of view: Make sure the target is larger than the
    unit's spot size. The smaller the tar-get the closer 
    measure distance. When acc-uracy is critical, make 
    sure the target is at least twice as large as the spot size.
4. Emissivity: Most organic materials and pa-inted or 
    oxidized surfaces have an emissiv-ity of  0.95 (pre- 
    set in the unit). Inaccurate readings will result from 
    measuring shiny or polished metal surfaces. To
    compensate, cover the surface to be measured with 
    mas-king tape or flat black paint. Measure the tape or 
    painted surface when the tape or painted reach the 
    same temperature as the  material underneath. 
    

5.3 @
60

3.0 @
36

1.5 @
12

0.30
0.95
0.95
0.70
0.50
0.90
0.85
0.95
0.95
0.95
0.94
0.90
0.93
0.85
0.98

Emissivity

                           

0.70
0.50
0.98
0.94
0.93
0.95
0.95
0.95
0.90
0.98
0.90
0.80
0.94
0.93
0.94

Emissivity

                           

Glass(plate)

Marterial

                           

Aluminum

Asbestos

Asphalt

Basalt

Brass

Brick

Carbon

Ceramic

Concrete

Copper

Dirt

Frozen food

Hot food

Ice

Marterial

                           

Iron

Lead

Limestone

Oil

Paint

Paper

Plastic

Rubber

Sand

Skin

Snow

Steel

Textiles

Water

Wood

LCD display: 
A measuring reading        
B measuring unit            G data hold icon                          
C laser on icon                H mode indicator                             
D back light on icon       I data storge / read icon                       
E battery power icon      J low temperature alarm icon                 
F scanning icon               K hight temperature alarm icon                   

               

 

2. Locating a hot spot: To find a hot spot aim  the
    thermometer outside the area of interest, then 
    scan across with up and down motions unitl you 
    locate the hot spot.(please turn on the laserto for 
    accurate measuring)
3. Diagram description
(1) Trigger: When turn on LCD display VER XX
     software version for 1 sec. And turn to di-splay 
    reading with SCAN icon. Release the trigger, 
    display reading with HOLD icon for 7 sec. Built 
    in auto power off in 30sec.
 (2) Laser / back light button: when back light turn 
       

Attention:
Red laser point only position the general direction the 
detection hole is the main parts measure the temperature

Red laser point 

detection hole

(Figure 3)

       on , any operations will remain back lig-ht for 
       10 sec. LCD indicate on/off status.

Repeatability 

Response time

Spectral response

Emissivity 

Relative humidity

Storage temperature

Weight/Dimensions

Power

Battery life  (Alkaline)

Distance to Spot Size

Specifications

Temperature 
range

Accuracy 

Ambient operating 

range

-20 to 60

 (-4 to 140

) without battery

100

(212

) to 600

(1112

)

±

2

or

±

2%

0

(32

) to 100

(212

)  

±

2

or

±

2%

-50

(-58

)to 0

(30

)  

±

3

or 

±

3%

whichever is greater

1% of reading or  1

500 mSec, 95% response

8-14 um

 0.10 to 1.00 adjustable (pre-set 0.95)

0 ~40

 (32 ~ 104

)

170G ; 175*100*49mm

Laser Models:12 hrs

12:1

  -50

~600

 

  -58

~1112

10-95% RH noncondensing

9v Alkaline or NiCd battery

AS842A

AS852B

  -50

~750

 

  -58

~1382

AS862A

   -50

~900

 

   -58

~1652

How it works
   Infrared thermometer measure the surface temperature

,

   of an object. The units optical system sense the object s
   emitted energy with different wavelength.It is collected  

,

   and focus onto a detector. The unit s electronics system
   translated the information into a temperature reading 
   which is displayed on the unit.

D:S=12:1

38mm@
300mm

75mm@
900mm

132mm@
1500mm

1.When take measurement, point thermome-ter toward
   the object to be measured and hold the yellow trigger.
   The object under test should be larger than the spot 
   size cal-culated by the field of view diagram.
2.Distance & spot size: As the distance from the object 
   increase, the spot size of meas-uring area becomes 
   larger.
     
    

    

Introduction
    Compact, rugged and easy to use. Just aim and push
    the button, read current surface te-mperatures in
    less than a second. Safely me-asure surface 
    temperatures of hot, hazardo-us or hard-to-reach
    objects without contact.

SENSOR

SMART

R

 AS842A
 AS852B

AS862A

           

MODEL

           

Отзывы: