APPENDIX

OSD MAP

DIP Switch Setting

ON

ON

ON

B02

ON

ERNITEC

ON

Pelco-P/D

MOLYNX

ON

ON

VICON

ON

SANTACHI

ON

Panasonic

ON

Samsung

ON

Kalatel

ON

LILIN

ON

DIAMOND

ON

HUNDA

ON

VLC

ON

ISD

ON

DYNACOLOR

ON

KTD410

T h e S w 1 c o n t a i n s t h e s e t t i n g f o r I D , p l e a s e r e f e r t o n e x t s e c t i o n
f o r s e t t i n g s . S w 2 c o n t a i n s s e t t i n g f o r P r o t o c o l , B a u d - r a t e a n d
Te r m i n a t i o n :

SW2 DIP 1 to 5 : Protocol

SW2 DIP 6 to7 : Baud-Rate

ON

2400

ON

4800

ON

9600

ON

19200

SW2 DIP 8 : Rs485 Termination

ON

ON

ON

OFF

Note: VIDO B02 Protocol is fully compatible with VIDO B01. For
previous version of Vido products please set to B02

9

English

Note: Depends on distance requirement, the Baud-Rate of
every protocol could be changed other than the originally
specefied settings. Make sure that your controller device can
work with the modified settings.

MAIN   MENU

SYSTEM

SETTING

CAMERA SETTING

FUNCTION SETTING

WINDOW

BLANKING

EXIT

ALARMS

SYSTEM

SETTING

EDIT DOME LABEL
INITIAL INFO
DISPLAY SETUP
MOTION
CLEAR

BACK
EXIT

PASSWORD SETUP
CLOCK SETTING
COMM SETTING

CAMERA SETTING

ZOOM SPEED

HIGH

DIGITAL ZOOM

ON

BLC MODE

OFF

SLOW SHUTTER

ON

ADVANCE SETTING

WDR MODE

2

E

BACK

XIT

ADVANCE SETTING 1

FUNCTION

SETTING

AE  MODE            AUTO

SHUTTER         N/A

IRIS            N/A

BRIGHT          N/A

W

MODE            AUTO

R  GAIN         N/A

B  GAIN         N/A

BACK

EXIT

B

HI-RESOLUION       OFF

PRESETS

SCAN

S C A N    N U M B E R                  0 1

S C A N    S P E E D                    6 3

S E T    L E F T    L I M I T

S E T    R I G H T    L I M I T

C L E A R    S C A N

R U N    S C A N

E D I T  S C A N  L A B E L

B A C K

E X I T

PATTERNS

P A T T E R N    N U M B E R                    1

P R O G R A M    P A T T E R N

R U N    P A T T E R N

C L E A R    P A T T E R N

E D I T    P A T T E R N    L A B E L

B A C K

E X I

T

EDIT

TOUR

٠٠-٠- ٠٠ ٠٠-٠- ٠٠ ٠٠-٠

٠٠-٠- ٠٠ ٠٠-٠- ٠٠ ٠٠-٠

٠٠-٠- ٠٠ ٠٠-٠- ٠٠ ٠٠-٠

٠٠-٠- ٠٠ ٠٠-٠- ٠٠ ٠٠-٠

٠٠-٠- ٠٠ ٠٠-٠- ٠٠ ٠٠-٠

P0-S-

P0-S-

P0-S-

- 00

- 00

- 00

- 00

- 00

TM

TM

TM

BACK

EXIT

ZONES

Z O N E S  N U M B E R                      1

S E T  L E F T  L I M I T

S E T  R I G H T  L I M I T

C L E A R  Z O N E

E D I T  Z O N E  L A B E L

B A C K

E X I T

DOME LABEL

OFF

PRESET LABEL

OFF

ZOOM LABEL

O

ZONE LABEL

OFF

DIRECTION LABEL

O

TEMPERATURE

LABEL

OFF

BACK

EXIT

FF

FF

TIME LABEL

OFF

DATE LABEL

OFF

MOTION

A U T O    F L I P                          O N

P R O P O R T I O N    P A N              O N

P A R K    T I M E                        0 0 5

P A R K    A C T I O N

P O W E R    U P    A C T I O N

F A N        E N A B L E D                0 4 0

B A C K

E X I T

NONE
NONE

IR HEADLIGHT

PASSWORD SETUP

INITIAL   INFO

S
PROTOCOL :

DOME  ADDRESS:  001

COMM:

00 . N.8.1

BACK

EXIT

/N XXXXXXXXXXXXXXX

FIRMWARE V1.10

VIDO B02

96

PRESET  NUMBER          001

SET  PRESET

SHOW  PRESET

CLEAR  PRESET

EDIT  PRESET LABEL

BACK

EXIT

LABEL: PRESET-01

BACK

EXIT

EDIT  PRESET  LABEL

LABEL:  AUTO  SCAN

BACK

EXIT

EDIT SCAN LABEL

L A B E L :  P A T T E R N - 1

B A C K

E X I T

EDIT PATTERN LABEL

LABEL: ZONE-1

BACK

EXIT

EDIT ZONE LABEL

LABEL:

BACK

EXIT

EDIT DOME LABEL

DISPLAY SETUP

ADVANCE SETTING

PRESETS

SCAN

PATTERNS

TOUR

ZONES

TIME RUNNING

BACK

EXIT

OLD PASSWORD  :  ******

NEW PASSWORD  :  ******

CONF PASSWORD :  ******

ENABLE PASSWORD: OFF

BACK

EXIT

CLEAR  ALL  ZONES

CLEAR  ALL  PRESETS

CLEAR  ALL  PATTERNS

CLEAR  ALL  TOURS

CLEAR  ALL  WINDOWS

FACTORY  DEFAULTS

RESTART

BACK

EXIT

TOUR

TOUR

RUN  TOUR
BACK

EXIT

NUMBER       1

EDIT TOUR
CLEAR TOUR

RESUME                            OFF
SEQUENCE                       002
RESET DELAY

020

ALARM CONTACT

N/A

ALARM SETTING
ARM SETTING
BACK
EXIT

ALARMS

S/N XXXXXXXXXXXXXXX

CONF: XXXXXXXXXXXXXXX

SITE ID      001

COMM SPEED 9600BPS

PROTOCOL   VIDO B02

BACK

EXIT

CLEAR

CLOCK SETTING

TIME:            00:00:00

DATE:            08/03/12

BACK

EXIT

COMM SETTING

TIME RUNNING

T I M E  C H A N N E L                  1

S T A R T  T I M E              0 0 : 0 0

E N D  T I M E

0 0 : 0 0

R U N N I N G

N O N E

B A C K

E X I T

WINDOW  NUMBER       01

EDIT  WINDOW

ENABLE  WINDOW       ON

CLEAR  WINDO

W

BACK
EXIT

WINDOW  BLANKING

ALARM NUMBER          001
ALARM ACTION

TOUR

ACTIVATE AUX             NONE
ALARM PRIORITY

HIGH

BACK
EXIT

ALARM SETTING

DAY

SUN

ARM STATE                     OFF
ARM TIME                       N/A
UNARM                            N/A
BACK
EXIT

ARM SETTING

IR HEADLIGHT

B A C K

E X I T

IR HEADLIGHT

MANUAL

DELATY TIME

02

IR CUT FILTER

BLACK

ACTIVATE AUX1

OFF

ON

SAE

ON

APPRO

ON

PHILIPS

ON

VIDEON

ON

PHILIPS M.

ON

AD M.

ON

UNIVISION

ON

SENSORMATIC

Содержание AU-G50IR-WB18

Страница 1: ...G50 G50IR G50Q G50L G50VL G50F G50M ENGLISH HIGH SPEED OUTDOOR PTZ CAMERA SERIES Operation Manual Ver 1 15 ...

Страница 2: ...pplication with extrem wet condition or area contains water or high humidity use the outdoor model instead When the indoor PTZ get wet turn off the power immediatly and send to qualified service personnel Do not point the camera to strong light source e g Sun Light Beamer or laser pointer This will cause permanent damage to the sensor and avoids the warranty Read this user s manual carefully befor...

Страница 3: ...ter the OSD Main Menu System Setting Edit dome label Initial Info Display Setup Motion Motion Advanced Setting Clear Password Setting Clock Setting Camera Setting IR CUT Filter Function Setting Presets Scan Pattern Tour Zones Time Running Window Blanking Alarms Language Appendix OSD Map ID Settings 1 1 1 1 2 2 2 2 2 3 3 3 4 4 4 4 4 5 5 5 5 5 5 6 6 6 7 7 7 7 8 8 8 9 10 Advance Setting 6 9 Dip Switc...

Страница 4: ... Controller Monitor DVR Connectors Accessories Unpacking Basic Setup Check List before installation 1 Telemetric Protocol setting 2 Dome ID setting 3 Termination setup 3 Necessary Accessories e g Power supply For telemetric control make sure that 1 All devices are set with same protocol and comm setting 2 All PTZ devices have an unique ID 3 Control cable Rs485 are connected properly For controller...

Страница 5: ...ide shows the maximum range of every baud rate assuming a AWG24 wire pair is used Note the range might be shorter than given here since the cable quality or interferences may affect the transmitted data and cause invalid command In star form connection it might be necessary to use RS 485 Distributor to ensure the signal quality of the transmission 2400 bps 1100m 700m 400m 4800 bps 1700m 9600 bps 1...

Страница 6: ...Make sure that your controller device supports these functions Zoom in PAN Zoom out TILT The PAN and TILT function are mostly performed from the Joystick on the keyboard Please refer to the user s manual of contoller device for operation instruction IRIS and FOCUS IRIS Open FOCUS Far IRIS Close In regular operation the focus and iris will be regulated automatically to achieve best image quality If...

Страница 7: ...N The input character starts to flash use UP or DOWN to select the desired character and RIGHT for next input Available characters appear in following order Use LEFT to move to previous character when edit In case you need to delete a character use the SPACE character Empty sign When finished press IRIS OPEN to save or use RIGHT to move to last character and next to exit the editing mode To dicard...

Страница 8: ...ABLED N A PRESET FREEZE N A HEAD DOWN OFF DEFOGGER 15 WIPER BACK EXIT IR HEADLIGHT EIS ANABLED PRESET FREEZE HEAD DOWN DEFOGGER WIPER Electronic Image Stablizer Depends on the camera model it might not be available Freezes the preset image When installing the PTZ reversed turn on this option Defogger function in the camera bay Starts the Wiper 5 English IR HEADLIGHT IR HEADLIGHT DELATY TIME 02 IR ...

Страница 9: ...lor Mode remains in the day mode Black IRC remains in night mode TIME Controlled by the time schedule When the IR Cutter should turn on given in day time When the IR Cutter should turn off given in day time Note This function is only available for models with Day Night ability please contact your local dealer in case of doubt improve the image quality in the Night modus Camera Setting Advanced Set...

Страница 10: ...t and right end of the PTZ range When the camera enters this area the name will be displayed on the screen which provides better orientation in surveillance application Up to 8 zones are supported ZONE NUMBER SET LEFT LIMIT SET RIGHT LIMIT CLEAR ZONE EDIT ZONE LABEL Currently selected zone Set the left end press IRIS OPEN to store or IRIS CLOSE to discard Set the right end press IRIS OPEN to store...

Страница 11: ...Disarm time Alarms Arm Setting LANGUAGE LANGUAGE ENGLISH BACK EXIT LANGUAGE Selectable between available languages Language OSD 8 English The Time Running function is a scheduled start for predefined action such as preset tour scan tour etc This dome supports up to 4 schedules Before setting this function please make sure that the system time has been set correctly TIME CHANNEL START TIME END TIME...

Страница 12: ...FT LIMIT SET RIGHT LIMIT CLEAR ZONE EDIT ZONE LABEL BACK EXIT DOME LABEL OFF PRESET LABEL OFF ZOOM LABEL O ZONE LABEL OFF DIRECTION LABEL O TEMPERATURE LABEL OFF BACK EXIT FF FF TIME LABEL OFF DATE LABEL OFF MOTION AUTO FLIP ON PROPORTION PAN ON PARK TIME 005 PARK ACTION POWER UP ACTION FAN ENABLED 040 BACK EXIT NONE NONE IR HEADLIGHT PASSWORD SETUP INITIAL INFO S PROTOCOL DOME ADDRESS 001 COMM 00...

Страница 13: ... 0 0 1 1 0 0 0 0 1 1 0 1 1 0 0 0 0 0 1 0 1 0 0 0 1 1 0 0 0 1 0 0 0 0 1 1 1 0 0 0 1 1 0 1 0 1 0 0 0 0 1 0 0 1 0 0 1 1 0 0 1 1 0 0 0 0 1 1 0 1 0 0 1 1 0 1 1 1 0 0 0 0 1 ID ID Switchnumber Sw1 Switchnumber Sw1 190 191 192 193 194 195 196 197 198 199 200 201 202 203 169 168 167 166 165 164 163 162 161 160 159 158 157 156 155 154 153 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 189 188 1...

Страница 14: ...db Electronic Shutter 1 1 to 1 10 000s 22 steps Lowest LUX 0 LUX Iris Zoom f 3 4mm 122 4 36X f 3 5mm 91 0 26X f 4 1mm 73 80 18X Focusing Range Automatic Manual Pan Movement 0 80 s Tilt Movement 0 60 s Preset Position 128 position in maximun Patrol Function 6 patrol patterns are stored in maximum Scanning Speed 0 5 30 s Self Study Plattern 40 sec Infrared Illuminator High Brightness LED X 36pcs Wav...

Страница 15: ...ic Shutter 1 1 to 1 10 000s 22 steps Lowest LUX 0 LUX Iris Zoom f 3 4mm 122 4 36X f 3 5mm 91 0 26X f 4 1mm 73 80 18X Focusing Range Automatic Manual Pan Movement 0 80 s Tilt Movement 0 60 s Preset Position 128 position in maximun Patrol Function 6 patrol patterns are stored in maximum Scanning Speed 0 5 30 s Self Study Plattern 40 sec Infrared Illuminator 24 x High Brightness LED 2 High Power OSRA...

Страница 16: ... 50db Electronic Shutter 1 1 to 1 10 000s 22 steps Lowest LUX 0 LUX Iris Zoom f 3 4mm 122 4 36X f 3 5mm 91 0 26X f 4 1mm 73 80 18X Focusing Range Automatic Manual Pan Movement 0 80 s Tilt Movement 0 60 s Preset Position 128 position in maximun Patrol Function 6 patrol patterns are stored in maximum Scanning Speed 0 5 30 s Self Study Plattern 40 sec Infrared Illuminator IR Laser Beamer Class 3A Wav...

Страница 17: ...sation Horizontal Resolution 470 TVL 470 TVL 530 TVL S N Ratio 50db Electronic Shutter 1 1 to 1 10 000s 22 steps Lowest LUX 0 LUX Iris Zoom f 3 4mm 122 4 36X f 3 5mm 91 0 26X f 4 1mm 73 80 18X Focusing Range Automatic Manual Pan Movement 0 80 s Tilt Movement 0 60 s Preset Position 128 position in maximun Patrol Function 6 patrol patterns are stored in maximum Scanning Speed 0 5 30 s Self Study Pla...

Отзывы: